Note
RS-485A corresponds to UART 5 on web and is for QR code scanner connecon at entrance by
default; RS-485C corresponds to UART 7 on web and is for card reader connecon at entrance by
default.
The SOC and MCU serial port are for maintenance and debugging use only.
Press the Reset buon for 5 s and the device will start to restore to factory sengs.
The DIP switch is for study mode seng. For detailed informaon about the DIP switch, see DIP
Switch Descripon.
The wiring diagram of extended interface of access control board is shown as follows.