EURO 46 V10 Programming Manual
Appendix 2 - Output Types
No. Output Type Active Restore
0000 Not Used
0001 Fire At a fire alarm activation. When a valid code is entered.
0002 Hold Up Any At a hold up (HU) /personal attack activation. When a valid code is entered.
0003 Intruder Any At an intruder alarm from any area. At first valid code entry.
0004 Final Set All When ALL areas are set. At code entry to unset.
0005 Misoperation (Abort) When the system is silenced after an intruder
alarm has been activated.
After two minutes.
0006 Confirmed Any After two intruder alarm activations. At the next code entry.
0007 Tamper Any Tamper alarm activation in any area. At code entry to silence
and at the end of the confirm time.
0008 Duress Any At a duress alarm in any area. When a valid code is entered
0009 HU Device Any At alarm on a HU input only, from any area (this
does not include the keypad HU).
When a valid code is entered.
0010 Gas At a gas alarm When a valid code is entered.
0011 Set Fail Pre-set time after the start of the exit time, if the
exit procedure is not complete.
At code entry to reset.
0012 Entry Deviation When a deviation from the entry route occurs
(during entry time).
At code entry to unset.
0013 Secure Intruder Any At alarm, after exit time started, until unset. At the first valid code entry and at end of
confirm time.
0014 Siren Any When the alarm is live. When the alarm is silenced or when the siren
timer expires.
0016 Strobe Any When the alarm is live. When the alarm is silenced or when the siren
timer expires.
0017 Omit Rearm Any Input omitted if active (or in alarm condition) at
the end of the confirmation time.
When the system is unset.
0018 Unconfirmed Any At any intruder of tamper alarm. At code entry to silence.
0019 Can Set All When all inputs but the ‘Entry Delay’ and ‘Follow’
inputs are closed.
If fault exists, and after final set.
0020 Exit Starts All At the start of the exit time to set the LAST area. At unset FIRST area (such as no longer fully
set).
0021 Exit Starts Any When the exit time starts to set the FIRST area. At code entry to unset LAST area.
0022 Final Set Any When ANY area has been set. At code entry to unset LAST area.
0023 Strobe Set Fail Works similar to output 016, but also fires if the ‘set fail’ timer expires.
0025 Keyswitch Unset This output turns on for five seconds when the system is disarmed via a key-switch input (pulsed
or latched).
0026 Set with Omit Active when the system is set with an input omitted.
0028 Power Fault Active during low volts and battery faults. Restores at code entry after the fault is cleared.
0029 Confirm Intruder Any When more than one intruder alarm activates. At next code entry.
0030 Confirm HU Any When more than one confirmed HU activates. At the next code entry.
0031 Entry Active during any entry time.
0032 Exit Active during any exit time.
0033 Entry / Exit Active during any entry or exit time.