50
EURO 46 V10 Programming Manual
Appendix 4 - Factory Defaults
Engineer Menu Sub-Menu
Defaults
2000 2002 Differences
INHIBIT FIRE/HU? Inhibit Fire/HU No [0]
SET DATE & TIME? Year (00-99) [07]
Month (1-12) [01]
Day (1-31) [01]
Hours (0-23) [00]
Minutes (0-59) [00]
DST Adjust? No [1]
WIRELESS DEVICE CONTROL? Inputs 9 - 32 Available
Bells 1 - 2 Available
Arming Stations 1 - 4 Available
CHANGE INPUTS? Inputs 1 - 76 Unused
Input In Area A
Input Areas Any [0]
Input Attributes
Chime No [0]
Omittable No [0]
Double Knock No [0]
Dual Trip No [0]
Normally Open No [0]
Walk Test No [0]
Monitor Activity No [0]
Special Log No [0]
Confirm Group [00]
Enter Name Input ##
Enter Location _
CHOOSE MODE? EOL Range 4K7/2K2 [1]
EOL Mode DR [1]
Input Response 300ms [03]
INSTALL ZEMs? ZEM Address [0]
ZEM Installed No [0]
CHANGE OUTPUTS? Endstation Outputs?
BELL O/P Siren Any [0014]
STB O/P Strobe Any [0016]
PGM O/P Not Used [0000]
XPGM1 O/P Not Used [0000]
XPGM2 O/P Not Used [0000]
ATE Pin 1 Fire [0001]
ATE Pin 2 HU Device Any [0009]