Operations
2. Release intermittent trigger switch or turn off
continuous setting on solution switch
approximately 1 foot before ending cleaning pass.
3. Push down on handle to raise vacuum shoe and
brush before moving to the next cleaning pass.
Overlap brush contact area a minimum of 1inch.
4. During operation, observe the following: The EX7
is equipped with clear internal covers to facilitate
operator viewing of dirty solution and vacuum air
flow.
During operation, observe the vacuum intake
cover. Large amounts of water or foam entering the
vacuum system can damage the vacuum motor.
NOTE: If you notice either condition, shut down the
machine immediately.
Empty recovery tank and/or add defoamer to
recovery tank.
5. Use right side of machine for cleaning against
walls.