3. Insert tools, accessories
Target plate PDA 50
Target plate PDA 51
Target plate PDA 52
Measuring extension PDA 71
Hand strap PDA 60
Soft pouch
PDA 65
Laser visibility glasses PUA 60
4. Technical data
Right of technical changes reserved.
Technical data Values
Power supply
3V DC AAಣsize batteries
Battery condition check Battery condition indicator with 4 segments showing
100%, 75%, 50%, 25% charge : No segments
shown: The batteries are exhausted
Measuring range 0.05…200 m
Typical measuring range without target plate Drywall panel, white: 100 m
Concrete, dry: 70 m
Brick, dry: 50 m
Accuracy
Typically ±1.0 mm for single and continuous
measurement
Smallest unit displayed
1mm
Beam diameter Beam length 10 m: Max. 6 mm
Beam length 50 m: Max. 30 mm
Beam length 100 m: Max. 60 mm
Basic operating modes
Single measuring, continuous measuring, calcula-
tion/functions
Display Illuminated dotಣmatrix display with permanent
indication of operating mode and battery condition
Laser
Visible 635 nm, Output power less than 1 mW: Laser
class 2
IEC 825ತ 1:2003CFR 21 § 1040 (FDA)
Automatic cutಣout Laser: 1 min
Tool: 10 min
Battery life Max. number of measurements with laser
beam switched on for a time of 10 s Al-
kaline 8,000…10,000 NiMH 6,000…8,000
Operating temperature range -10…+50°C
Storage temperature -30…+70°C
Protection class (except battery compartment) IP 54 protection against dust and water jets
IEC 529
en
22