8 English 2068470
*2068470*
Activate scale
Switch signal tone on / off
Select laser on constantly
Select automatic brightness sensor
Calibrate inclination sensor
Display information about the tool
Reset to default settings
Indirect measurement submenu
Indirect horizontal distance measurement
Indirect vertical distance measurement
Take measurements on ceilings
Indirect vertical distance measurement II
3.4 Items supplied
Laser range meter, two batteries, operating instructions, manufacturer’s
certificate.
Other system products approved for use with this product can be found
at your local Hilti Store or at: www.hilti.group
4 Technical data
Rated voltage
3 V
Rated current
400 mA
Maximum site elevation above datum
2,000 m
(6,561 ft - 10 in)
Maximum relative humidity
80 %
Operating temperature
−10 ℃ … 50 ℃
(14 ℉ … 122 ℉)
Distance measurement accuracy (2σ, stan-
dard deviation)
±1.0 mm
Inclination measurement accuracy (2σ, stan-
dard deviation)
±0.2°
Output power, laser
< 1 mW
Wavelength, laser
639 nm
(0.0000252 in)