4 Technical data
4.1 Technical data
SF 2A SFD 2-A
Rated voltage
10.8 V 10.8 V
Weight
1.1 kg
(2.4 lb)
1 kg
(2 lb)
Speed in 1st gear
0 /min …
400 /min
0 /min …
400 /min
Speed in 2nd gear
0 /min …
1,500 /min
0 /min …
1,500 /min
Torque
0 Nm …
3.5 Nm
0 Nm …
3.5 Nm
Torque (drill symbol)
12 Nm 12 Nm
4.2 Battery
Battery operating voltage
10.8 V
Ambient temperature
−17 ℃ … 60 ℃
(1 ℉ … 140 ℉)
Storage temperature
−20 ℃ … 40 ℃
(−4 ℉ … 104 ℉)
Charging temperature
−10 ℃ … 60 ℃
(14 ℉ … 140 ℉)
5 Operation
5.1 Inserting/removing the battery 1
CAUTION
Risk of injury. The drill/driver may start inadvertently.
▶ Before fitting the battery, check that the drill/driver is switched off and
that the switch safety lock is activated.
CAUTION
Electrical hazard. Dirty contacts may cause a short circuit.
▶ Before inserting the battery, check to ensure that the battery terminals
and the contacts in the drill/driver are free from foreign objects.
CAUTION
Risk of injury. If the battery is not fitted correctly it may drop out and fall.
▶ Check that the battery is securely seated in the tool so that it cannot drop
out and fall, thereby presenting a hazard to other persons.
Printed: 07.01.2019 | Doc-Nr: PUB / 5174907 / 000 / 02