Installation GRS1020/1120/1030/1130
Release
03
01/2017
47
Power supply
Supply voltage
with the
characteristic
value C
Nominal voltage DC 24 V ... 48 V
Voltage range DC incl.
maximum tolerances
18 V ... 60 V
Connection type 2-pin terminal block
Power loss buffer > 10 ms at 20.4 V DC
Back-up fuse for each voltage
input
Nominal rating:
Characteristic:
6.3 A
slow blow
Overload current protection at
input
Non-replaceable fuse
Peak inrush current < 7 A
Signal contact Nominal value for AC I
max
=2A at U
max
=230V
Nominal value for DC I
max
=2A at U
max
=30V
I
max
=0.2A at U
max
= 125 V
a
I
max
=0.1A at U
max
= 250 V
a
Climatic
conditions during
operation
Ambient air temperature
b
Standard
up to 6562 ft ASL
(2000 m ASL)
above 6562 ft ASL
(2000 m ASL)
+32 °F ... +140 °F
(0 °C ... +60 °C)
+32 °F to +122 °F
(0 °C ... +50 °C)
Extended
c
,
d
e
up to 6562 ft ASL
(2000 m ASL)
above 6562 ft ASL
(2000 m ASL)
40 °F ... +158 °F
(40 °C ... +70 °C)
40 °F ... +140 °F
(40 °C ... +60 °C)
Extended with
conformal coating
b,c
above 6562 ft ASL
(2000 m ASL)
above 6562 ft ASL
(2000 m ASL)
40 °F ... +158 °F
(40 °C ... +70 °C)
40 °F ... +140 °F
(40 °C ... +60 °C)
Humidity 5 % ... 95 % (non-condensing)
Air pressure at least 600 hPa (+13123 ft; +4000 m)
maximum 1060 hPa (1312 ft; 400 m)
Climatic
conditions during
storage
Ambient air temperature
a
40 °F ... +185 °F
(40 °C ... +85 °C)
Humidity 5 % ... 95 % (non-condensing)
Air pressure at least 600 hPa (+13123 ft; +4000 m)
maximum 1060 hPa (1312 ft; 400 m)
Pollution degree 2
Protection
classes
Laser protection Class 1 in compliance with IEC 60825-1
Degree of protection IP20
a. Not UL 60950 certified.
b. Temperature of the ambient air at a distance of 2 inches (5 cm) from the device
c. If you are using SFP modules without the “EEC” extension, an operating temperature of
+32 °F to +140 °F (0 °C to +60 °C) applies for your device. See “Accessories” on page 54.
d. Applies to device variants GRS....-8T8Z... with the extended temperature range:
e. If more than 4 SFP transceivers are used, the maximum operating temperature is reduced
by 2 K per additional SFP transceiver.