Installation GRS1020/1120/1030/1130
Release
03
01/2017
51
Damped vibration – DC supply connection
EN 61000-4-12
IEEE C37.90.1
line/ground 2.5 kV
EN 61000-4-12
IEEE C37.90.1
line/line 1 kV
Damped oscillation - data line
EN 61000-4-12
IEEE C37.90.1
line/ground 2.5 kV
EN 61000-4-12 line/line ± 1 kV
Pulse magnetic fields
EN 61000-4-9 300 A/m
a. EN 61131-2, CE, FCC – applies to all devices
b. Merchant Navy – applies to devices with the approval codes U9, UT, UX, UY, VU
c. EN 50121-4 – applies to devices with the certification codes VT, T9, TY
d. EN 61850-3, IEEE 1613 – applies to devices with the certification codes V9, VY, VU, VT
Stability Standard
applications
a
a. EN 61131-2, CE, FCC – applies to all devices
Merchant Navy
b
b. Merchant Navy – applies to devices with the approval codes U9, UT, UX, UY, VU
Railway applications
(trackside)
c
c. EN 50121-4 – applies to devices with the certification codes VT, T9, TY
Substation
applications
d
d. EN 61850-3, IEEE 1613 – applies to devices with the certification codes V9, VY, VU, VT
IEC 60068-2-6, test Fc Vibration 5 Hz ... 8.4 Hz with
0.14 in. (3.5 mm)
amplitude
8.4 Hz ... 150 Hz
with 1 g
2 Hz ... 13.2 Hz with
0.04 in. (1 mm)
amplitude
13.2 Hz ... 200 Hz with
0.7 g
2 Hz ... 9 Hz with
0.12 in. (3 mm)
amplitude
9 Hz ... 200 Hz
with 1 g
200 Hz ... 500 Hz
with 1.5 g
IEC 60068-2-27, test Ea Shock 15 g at 11 ms 10 g at 11 ms