Installation GRS1020/1120/1030/1130
Release
03
01/2017
37
For every supply voltage to be connected, perform the following steps:
Remove the power connector from the device.
Connect the wires according to the pin assignment on the device with the
clamps.
Fasten the wires connected by tightening the terminal screws.
2.4.2 Supply voltage with the characteristic value M
You will find information on the characteristic values here:
“Device name and product code” on page 16
You have the option of supplying the supply voltage redundantly, without
load distribution.
Both supply voltage inputs are uncoupled.
Figure 6: Supply voltage with the characteristic value M: 3-pin terminal block with
screw locking
Type of the voltages
that can be connected
Specification of the supply
voltage
Connections
DC voltage M Rated voltage range DC
110 V ... 250 V
Voltage range DC incl.
maximum tolerances
88 V ... 288 V
+/L
−/N
Plus terminal of the supply
voltage
Minus terminal of the supply
voltage
Protective conductor
AC voltage M Rated voltage range AC
110 V ... 240 V, 50 Hz ... 60 Hz
Voltage range AC incl.
maximum tolerances
88 V ... 276 V, 47 Hz ... 63 Hz
+/L
−/N
Outer conductor
Neutral conductor
Protective conductor
Table 14: Supply voltage with the characteristic value M: type and specification of
the supply voltage, connections