21
Error
Code
Error Cause Elimination
E12
Fallen below lower
limit value in
measuring channel
"force main
boom(MB) right"
Cable between the central unit
and the force transducer
defective or loose. Water
inside the plug of the
transducer
Force transducer defective
Electronic component in the
measuring channel is
defective.
Check cable as well as plugs,
replace, if need be
Replace force transducer
Replace sensor unit
E13
Fallen below lower
limit value in
measuring channel
"force jib right"
Cable between the central unit
and the force transducer
defective or loose. Water
inside the plug of the
transducer
Force transducer defective
Electronic component in the
measuring channel is defective
Check cable as well as plugs,
replace, if need be
Replace force transducer
Replace sensor unit
E14
Fallen below lower
limit value in
measuring channel
"force main boom
left"
Cable between the central unit
and the force transducer
defective or loose. Water
inside the plug of the
transducer
Force transducer defective
Electronic component in the
measuring channel is
defective.
Check cable as well as plugs,
replace, if need be
Replace force transducer
Replace sensor unit
E15
Fallen below lower
limit value in
measuring channel
"angle main boom
foot"
Cable between the central unit
and the angle sensor defective
or loose. Water inside the plug
of the angle sensor
Angle potentiometer defective
Electronic component in the
measuring channel defective.
Check cable as well as plugs,
replace, if need be.
Replace angle sensor
Replace sensor unit
E16
Fallen below lower
limit value in
measuring channel
"angle luffing jib
foot"
refer to E15
refer to E15
E17
Fallen below lower
limit value in
measuring channel
"force luffing jib left"
refer to E14
refer to E14