Operator’s Manual
22
Error
Code
Error Cause Elimination
E18
Fallen below lower
limit value in
measuring channel
"MB backstip
pressure"
Cable between the central unit
and the pressure transducer
defective or loose. Water
inside the plug of the
transducer
Force transducer defective
Electronic component in the
measuring channel is
defective.
Check cable as well as plugs,
replace, if need be
Replace force transducer
Replace sensor unit
E19
Fallen below lower
limit value in
measuring channel "
luffing jib backstip
pressure "
Cable between the central unit
and the pressure transducer
defective or loose. Water
inside the plug of the
transducer
Force transducer defective
Electronic component in the
measuring channel is
defective.
Check cable as well as plugs,
replace, if need be
Replace force transducer
Replace sensor unit
E1B
Fallen below lower
limit value in
measuring channel
"angle luffing jib tip"
refer to E15
refer to E15
E1C
Fallen below lower
limit value in
measuring channel
"angle main boom tip"
Cable between the central unit
and the angle sensor defective
or loose. Water inside the plug
of the angle sensor
Angle potentiometer defective
Electronic component in the
measuring channel defective.
Check cable as well as plugs,
replace, if need be.
Replace angle sensor
Replace sensor unit
E1D
Fallen below lower
limit value in
measuring channel
"angle super lift mast"
Cable between the central unit
and the angle sensor defective
or loose. Water inside the plug
of the angle sensor
Angle potentiometer defective
Electronic component in the
measuring channel defective.
Check cable as well as plugs,
replace, if need be.
Replace angle sensor
Replace sensor unit
E22
Upper limit value in
measuring channel
"force main boom
right" has been
exceeded.
refer to E12
refer to E12
E23
Upper limit value in
measuring channel
"force jib right" has
been exceeded.
refer to E13
refer to E13