25
Error
Code
Error Cause Elimination
E82
Too large difference
of the luffing jib
angles at tip and base
jib.
The angle as to the horizontal
on the jib head exceeds the
luffing jib angle by more than
5 degrees.
Check angle sensor on the jib
head.
Check angle sensor on the jib
base.
E83
Maximum force in the
main boom pendants
exceeded
The force actuating on the
main boom pendants has
exceeded the programmed
value
Reduce force acting on the
main boom pendants.
E84
Wrong rigging
condition.
The selected rigging condition
is not contained in the crane
data file.
Select another rigging
condition
Check the programming in the
crane data file.
E85
Error in the radius
determination
The computed radius is too
small (negative deflection)
Check the programming in the
crane data file.
E88
Faulty main boom
position during luffing
jib operation
During luffing jib operation
the main boom is not in the
prescribed angle range
Angle measurement of main
boom defective.
Luff boom to the permitted
range
Check angle measurement of
the main boom.
E89
Faulty positioning of
the jib during
operation with fixed
angle to the main
boom or to a luffing
jib
During operation with fixed
jib to the main boom, the jib is
not in the permitted angle
range
Angle measurement of the jib
defective
Luff the auxiliary jib to the
permitted range
Verify angle measurement of
the auxiliary jib.
E94
No data transmits
from central unit to
console
Can bus defective
The system data transmission
defective
Restart system
Check Can bus cable
E98
LMI watchdog
activated
LMI processing time limit
exceeded
Reset system
Connect PC terminal and
watch error messages
EAB
Short circuit in the
A2B switch circuit
Short circuit in the A2B
switch
Short circuit in the cable to the
A2B switch
Replace A2B switch
Replace cable to the A2B
switch
EAC
A2B switch circuit
disconnected
Disconnected cable in the
A2B switch
Disconnected cable to the
A2B switch
Connect or replace cable in
the A2B switch
Connect or replace cable to
the A2B switch
EAD
No valid A2B switch
status
Sensor wrong function
CAN bus delay
Replace A2B switch
Replace cable to the A2B
switch