Operator’s Manual
24
Error
Code
Error Cause Elimination
E37
Error in the logical
program flow
System program file is
defective
Flash-EPROM defective
Upload valid system software
Replace central unit
E38
System program and
crane data file do not
match.
The system program in the
LMI does not match to the
programming in the crane data
file
Upload valid system program
file or the valid crane data file
E39
System program and
load chart file do not
match
The system program in the
LMI and the programming in
the load chart file do not
match.
Upload valid system program
file or the valid load chart file
E3A
crane data file and
load chart file do not
match
Crane type in dat file and load
chart file is different
Cange dat file and/or load
chart file
E43
Error in the
write/read memory,
(RAM)
Write/read memory (RAM) or
central unit defective.
Replace central unit
E51
Error in the crane
data file
No valid data in the crane
data file.
Flash-EPROM defective
Upload valid crane data file
Replace central unit
E52
Error in load chart
file.
No valid data in the load chart
file
Flash-EPROM defective
Upload valid load chart file
Replace central unit
E56
Error in crane data
file.
No valid data in the crane
data file during calibration.
Flash-EPROM defective
Restore or upload valid crane
data file
Replace central unit
E57
Error in serial crane
data file.
Calibration data file does not
contain valid data.
Flash-EPROM defective
Upload calibration data file
Replace central unit
E60
The number of the
selected File base and
the programmed value
are not identical
No valid data in the load chart
file
Base number not programmed
Load chart file wrongly
programmed
Upload valid load chart file
Program the correct base
number (1 for base 1, 2 for
base 2)
Check base programming in
the load chart file.
E61
Error in the CAN bus
data transfer for all
CAN units
CAN Bus cable between the
central unit and the sensor unit
defective or not connected.
Can bus port in the central unit
defective
Short circuit in a CAN Bus
cable
Check the connection between
the central unit and the
sensor units
Replace the central unit
Replace Can Bus cable
E81
Too large difference
of the boom angles at
tip and base boom (if
avail.)
The angle as to the horizontal
on the boom head exceeds the
main boom angle by more
than 5 degrees.
Check angle sensor on the
boom head.
Check angle sensor on the
base boom.