3 Making basic settings
The IP parameters must be entered when the device is installed for the first
time. The device provides 6 options for configuring IP addresses:
Entry via V.24 connection
Entry using the HiDiscovery protocol via the application HiDiscovery or
Industrial HiVision
Configuration via BOOTP
Configuration via DHCP
Configuration via DHCP Option 82
Auto Configuration Adapter
Further information on the basic settings of the device can be found in the
“Basic Configuration” user manual on the CD/DVD.
3.0.1 Default settings
IP address: The device looks for the IP address using DHCP
Password for management:
Login: user; password: public (read only)
Login: admin; password: private (read and write)
Parameters that can be set via the management are set to pre-defined
values in accordance with the MIB
V.24 data rate: 9,600 Baud
Ring redundancy: disabled
Ethernet ports: link status is not evaluated (signal contact)
Optical 100 Mbit/s ports: 100 Mbit/s, full duplex
All other ports: autonegotiation
Ring manager disabled
Stand-by coupling: disabled
Port 4 = control port, port 3 = coupling port for red. Ring coupling

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hirschmann MACH 1030 and is the answer not in the manual?

Hirschmann MACH 1030 Specifications

General IconGeneral
BrandHirschmann
ModelMACH 1030
CategoryNetwork Router
LanguageEnglish

Related product manuals