Diagnostics
RM Web L2B
Release
5.3
05/2012
7.5
Device Status
113
Select "Generate Trap" in the "Trap Configuration" field to activate the
sending of a trap if the device state changes.
Note: With a non-redundant voltage supply, the device reports the absence
of a supply voltage. If you do not want this message to be displayed, feed the
supply voltage over both inputs or switch off the monitoring (see on page 114
“Signal contact”).
Ring Redundancy Monitor/ignore ring redundancy (for HIPER-Ring only in Ring Manager
mode).
On delivery, ring redundancy is not monitored.
If the device is a normal ring subscriber and not the ring manager, it
reports the following:
nothing (for the HIPER-Ring)
detected errors in the local configuration (for Fast HIPER-Ring and
for MRP)
Ring/Network
coupling
Monitor/ignore the redundant coupling operation.
On delivery, no monitoring of the redundant coupling is set.
For two-Switch coupling with control line, the slave additionally reports
the following conditions:
– Incorrect link status of the control line
– Partner device is also a slave (in standby mode).
Note: In two-Switch coupling, both Switches must have found their
respective partners.
a. The configurations are non-matching if only one file exists or the two files do not have the
same content.
Name Meaning
Table 28: Device Status