10
Installation RSPE 30/32/35/37
Release
 
12
 
10/2015
 Relevant for use in explosion hazard areas (Hazardous 
Locations, Class I, Division 2):
Control Drawing for RSPE devices according to Class 1 Division 2 Hazardous Locations
Rev.: 1 Document No.:  000182303DNR Page 1/2
For Use in Hazardous Locations Class I Division 2 Groups A, B, C, D:
Only allowed  for RSPE/RSPM model No´s. which are individually labeled
 “FOR USE IN HAZARDOUS LOCATIONS”.
 
This equipment is suitable for use in Class I, Division 2, 
Groups A, B, C, and D OR non-hazardous locations only.  
1RQLQFHQGLYH¿HOGZLULQJFLUFXLWVPXVWEHZLUHGLQDFFRUGDQFHZLWKWKH1DWLRQDO(OHFWULFDO&RGH
(NEC), NFPA 70, article 501.
WARNING – EXPLOSION HAZARD
Substitution of any components may impair suitability for hazardous locations or explosive 
atmospheres.
WARNING – EXPLOSION HAZARD
Do not disconnect equipment unless power has been switched off or the area is known to be 
known to be non-hazardous.
AVERTISSEMENT – RISQUE D‘EXPLOSION
La substitution  de tout composant peut rendre ce materiel incompatible pour une utilisation en 
Classe I, Division 2.
AVERTISSEMENT – RISQUE D‘EXPLOSION
Ne pas debrancher tant que le circuit est sous tension a moins que l‘emplacement soit connu pour 
QHFRQWHQLUDXFXQHFRQFHQWUDWLRQGHJD]LQÀDPPDEOH