15
Location Requirements
Electrical Requirements
The air conditioner should be connected to a 220-
240V, 50 HZ, 20-amp fuse grounded 3 prong outlet.
The use of a time-delay fuse or time-delay circuit breaker is
recommended.
All wiring must comply with local and the national electrical
codes and be installed by a qualified electrician. If you have
any questions, contact a qualified electrician.
portable
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
WARNING
fire, or electrical shock.
NOTES:
The flexible exhaust hose allows placement of the air
conditioner between 60 cm and 170 cm from window or door.
For appliances with supplementary heaters, the minimum
clearance from the appliances to combustible surfaces is 100cm.
Portable air conditioners are designed as supplemental
cooling to local areas within a room.
NOTES:
To ensure proper ventilation, keep the required distance from
the return air outlet to the wall or other obstacles at least 60
cm.
Do not block the air outlet.
Provide easy access to the grounded 3 prong outlet.
Vertical Slide Widow
Horizontal Slide Window
60 cm - 170 cm
60 cm - 170 cm
100 cm
100 cm
Unpack the Air Conditioner
Remove packaging materials
Remove and dispose of/recycle packaging materials.
Remove tape and glue residue from surfaces before turning
on the air conditioner. Rub a small amount of liquid dish soap
over the adhesive with your fingers. Wipe with warm water
and dry.
Do not use sharp instruments, rubbing alcohol, flammable
fluids, or abrasive cleaners to remove tape or glue. These
products can damage the surface of your air conditioner.
Handle the air conditioner gently.
WARNING
Excessive Weight Hazard
Use two or more people to move and install
air conditioner.
Failure to do so can result in back or other injury.
INSTALLATION INSTRUCTIONS
combustible surfaces
combustible surfaces

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hisense APC09 and is the answer not in the manual?

Hisense APC09 Specifications

General IconGeneral
TypeMonobloc mobile air conditioner
Timer typeDigital
Noise level64 dB
Airflow (high speed)380 m³/h
Refrigerating mediumR290
Dehumidifier functionYes
Cooling capacity (max)- BTU/h
Dehumidifying capacity1 l/h
Timer duration (maximum)24 h
Air conditioner functionsCooling, Dehumidifying
Refrigerating medium weight260 g
Suitable for room area up to36 m²
Cooling capacity in watts (max)- W
Cooling capacity in watts (nominal)2600 W
Cooling energy efficiency (EER, W/W)2.6
Heating energy efficiency (COP, W/W)-
AC input voltage220 - 240 V
AC input frequency50 Hz
Energy efficiency class (cooling)A
Energy efficiency class (heating)No
Hourly energy consumption (cooling)- kWh
Product colorWhite
Weight and Dimensions IconWeight and Dimensions
Depth325 mm
Width430 mm
Height690 mm
Weight30000 g
Package depth380 mm
Package width480 mm
Package height880 mm
Package weight34000 g

Related product manuals