Safety precautions
9
CAUTION
Any person who is involved with working on or breaking into a refrigerant circuit
should hold a current valid certificate from an industry-accredited assessment
authority, which authorises their competence to handle refrigerants safely in
accordance with an industry recognised assessment specification.
Servicing shall only be performed as recommended by the equipment
manufacturer.
Maintenance and repair requiring the assistance of other skilled personnel
shall be carried out under the supervision of the person competent in the use of
flammable refrigerants.
Do not use means to accelerate the defrosting process or to clean, other than
those recommended by the manufacturer.
Appliance shall be installed, operated and stored in a room with a floor area
larger than: APC09(10.3m
2
), APH09(14.4m
2
), APC12(13.6m
2
), APH12(14.4m
2
)
2 2
+AP-12CR4GF*S00(13.6m ), +AP-12HR4GF*S00(14.4m ).
The pipe-work shall be complianced with national gas regulations.
Spaces where refrigerant pipes shall be compliance with national gas
regulations.
The maximum refrigerant charge amount is 0.936 kg.
Mechanical connectors used indoors shall comply with ISO 14903. When
mechanical connectors are reused indoors, sealing parts shall be renewed.
When flared joints are reused indoors, the flare part shall be re-fabricated.
The installation of pipe-work shall be kept to a minimum.
Mechanical connections shall be accessible for maintenance purposes.
Servicing shall be performed only as recommended by the manufacturer.
All working procedure that affects safety means shall only be carried by
competent persons.
Explanation of symbols displayed on the indoor unit or outdoor unit.
Fuse parameter of the machine:
APC09(T3.15A, 250V), APH09(T5A, 250V),
APC12(T3.15A, 250V), APH12(T3.15A, 250V).
WARNING
This symbol shows that this appliance uses a flammable
refrigerant.
If the refrigerant is leaked and exposed to an external
CAUTION
This symbol shows that the operation manual should be
read carefully.
CAUTION
This symbol shows that a service personnel should be
handling this equipment with reference to the
installation manual.
CAUTION
This symbol shows that information is available such as
the operating manual or installation manual.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hisense APH12 and is the answer not in the manual?

Hisense APH12 Specifications

General IconGeneral
TypeSplit system
Multi-splitNo
Timer typeDigital
Noise level64 dB
Number of speeds3
Remotely operatedYes
Airflow (high speed)380 m³/h
Refrigerating mediumR290
Cooling capacity (max)- BTU/h
Dehumidifying capacity1.3 l/h
Timer duration (maximum)24 h
Air conditioner functionsCooling, Dehumidifying, Fan, Heating
Refrigerating medium weight300 g
Suitable for room area up to36 m²
Cooling capacity in watts (max)- W
Cooling capacity in watts (nominal)3500 W
Heating capacity in watts (nominal)3000 W
Cooling energy efficiency (EER, W/W)2.6
Heating energy efficiency (COP, W/W)2.8
AC input voltage220 - 240 V
AC input frequency50 Hz
Energy efficiency class (cooling)A
Energy efficiency class (heating)A+
Hourly energy consumption (cooling)- kWh
Display typeLED
Product colorWhite
Weight and Dimensions IconWeight and Dimensions
Depth382 mm
Width442 mm
Height750 mm
Weight35000 g
Package weight39500 g

Related product manuals