Safety precautions
Precautions for using R290 refrigerant
2
However, pay attention to the following points:
The basic installation work procedures are the same as the conventional refrigerant (R22 or R410A).
CAUTION
1. Transport of equipment containing flammable refrigerants
Compliance with the transport regulations
2. Marking of equipment using signs
Compliance with local regulations
3. Disposal of equipment using flammable refrigerants
Compliance with national regulations
4. Storage of equipment/appliances
The storage of equipment should be in accordance with the manufacturer's
instructions.
5. Storage of packed (unsold) equipment
Storage package protection should be constructed such that mechanical
damage to the equipment inside the package will not cause a leak of the
refrigerant charge.
The maximum number of pieces of equipment permitted to be stored together
will be determined by local regulations.
6. Information on servicing
6-1 Checks to the area
Prior to beginning work on systems containing flammable refrigerants, safety
checks are necessary to ensure that the risk of ignition is minimised. For repair
to the refrigerating system, the following precautions shall be complied with
prior to conducting work on the system.
6-2 Work procedure
Work shall be undertaken under a controlled procedure so as to minimise the
risk of flammable gas or vapour being present while the work is being
performed.
6-3 General work area
All maintenance staff and others working in the local area shall be instructed
on the nature of work being carried out. Work in confined spaces shall be
avoided.
The area around the workspace shall be sectioned off. Ensure that the
conditions within the area have been made safe by control of flammable
material.
6-4 Checking for presence of refrigerant
The area shall be checked with an appropriate refrigerant detector prior to and
during work, to ensure the technician is aware of potentially flammable
atmospheres.
Ensure that the leak detection equipment being used is suitable for use with
flammable refrigerants, i.e. non-sparking, adequately sealed or intrinsically
safe.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hisense APH12 and is the answer not in the manual?

Hisense APH12 Specifications

General IconGeneral
TypeSplit system
Multi-splitNo
Timer typeDigital
Noise level64 dB
Number of speeds3
Remotely operatedYes
Airflow (high speed)380 m³/h
Refrigerating mediumR290
Cooling capacity (max)- BTU/h
Dehumidifying capacity1.3 l/h
Timer duration (maximum)24 h
Air conditioner functionsCooling, Dehumidifying, Fan, Heating
Refrigerating medium weight300 g
Suitable for room area up to36 m²
Cooling capacity in watts (max)- W
Cooling capacity in watts (nominal)3500 W
Heating capacity in watts (nominal)3000 W
Cooling energy efficiency (EER, W/W)2.6
Heating energy efficiency (COP, W/W)2.8
AC input voltage220 - 240 V
AC input frequency50 Hz
Energy efficiency class (cooling)A
Energy efficiency class (heating)A+
Hourly energy consumption (cooling)- kWh
Display typeLED
Product colorWhite
Weight and Dimensions IconWeight and Dimensions
Depth382 mm
Width442 mm
Height750 mm
Weight35000 g
Package weight39500 g

Related product manuals