Safety precautions
5
CAUTION
live in the presence of a flammable atmosphere. The test apparatus shall be at
the correct rating.
Replace components only with parts specified by the manufacturer.
Other parts may result in the ignition of refrigerant in the atmosphere from a
leak.
9. Cabling
Check that cabling will not be subject to wear, corrosion, excessive pressure,
vibration, sharp edges or any other adverse environmental effects.
The check shall also take into account the effects of aging or continual
vibration from sources such as compressors or fans.
10.Detection of flammable refrigerants
Under no circumstances shall potential sources of ignition be used in the
searching for or detection of refrigerant leaks.
A halide torch (or any other detector using a naked flame) shall not be used.
11.Leak detection methods
The following leak detection methods are deemed acceptable for systems
containing flammable refrigerants:
Electronic leak detectors shall be used to detect flammable refrigerants, but
the sensitivity may not be adequate, or may need re-calibration. (Detection
equipment shall be calibrated in a refrigerant-free area.)
Ensure that the detector is not a potential source of ignition and is suitable
for the refrigerant used.
Leak detection equipment shall be set at a percentage of the LFL of the
refrigerant and shall be calibrated to the refrigerant employed and the
appropriate percentage of gas (25 % maximum) is confirmed.
Leak detection fluids are suitable for use with most refrigerants but the use
of detergents containing chlorine shall be avoided as the chlorine may react
with the refrigerant and corrode the copper pipe-work.
If a leak is suspected, all naked flames shall be removed/ extinguished.
If a leakage of refrigerant is found which requires brazing, all of the
refrigerant shall be recovered from the system, or isolated (by means of shut
off valves) in a part of the system remote from the leak.
Oxygen free nitrogen (OFN) shall then be purged through the system both
before and during the brazing process.
12.Removal and evacuation
When breaking into the refrigerant circuit to make repairs – or for any other
purpose – conventional procedures shall be used.
However, it is important that best practice is followed since flammability is a
consideration.
The following procedure shall be adhered to:
Remove refrigerant;
Purge the circuit with inert gas;

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hisense APH12 and is the answer not in the manual?

Hisense APH12 Specifications

General IconGeneral
TypeSplit system
Multi-splitNo
Timer typeDigital
Noise level64 dB
Number of speeds3
Remotely operatedYes
Airflow (high speed)380 m³/h
Refrigerating mediumR290
Cooling capacity (max)- BTU/h
Dehumidifying capacity1.3 l/h
Timer duration (maximum)24 h
Air conditioner functionsCooling, Dehumidifying, Fan, Heating
Refrigerating medium weight300 g
Suitable for room area up to36 m²
Cooling capacity in watts (max)- W
Cooling capacity in watts (nominal)3500 W
Heating capacity in watts (nominal)3000 W
Cooling energy efficiency (EER, W/W)2.6
Heating energy efficiency (COP, W/W)2.8
AC input voltage220 - 240 V
AC input frequency50 Hz
Energy efficiency class (cooling)A
Energy efficiency class (heating)A+
Hourly energy consumption (cooling)- kWh
Display typeLED
Product colorWhite
Weight and Dimensions IconWeight and Dimensions
Depth382 mm
Width442 mm
Height750 mm
Weight35000 g
Package weight39500 g

Related product manuals