4.2.9 Common error
1 Reading Device ID have different ID codes.
Check the SecureCRT window whether close.
2When input key, appear” Input format Error”
Check Mstv_tool --open debugport -- 3rd generation” whether selected .
3ISP_Tool connected failure
Close the SecureCRT, check whether “ ” in front of “UseSWI2C” of “Config” .
4If ISP_Tool connected appear error “ Device not selected,yet”;
Reduce the I2C speed setting figure lower “Roughly speed” about “200KHz” and have a try.
5After USB upgrade, appear “
mtdoops: mtd device (mtddev=name/number) must be suppliedKernel
panic - not syncing: VFS: Unable to mount root fs on unknown-block(179,4)
Reason: After burn mboot and before USB upgrade, forget to clear the
zone schema.
Don’t burn mboot againONLY restart TV with “cu” demand to USB upgrading again
in mboot .