37
INSTALLATION & MAINTENANCE MANUAL
10.1.2 Zone Operation Setting
This function is to set operation (ON/OFF) of individual zone.
Step1. Press "
" or " " to select "ON/OFF".
Step2. Press "
" or " " to set zone operation.
NOTES:
When "Spill zone control on" displays in the bottom le corner, spill zone enters automatic control, and the
actual state of the zone may not be consistent with the set state.
During Setback operation, Zoning Kit does not accept zone settings.
Even if the parameters are modied, they will be restored aer one second.
10.1.3 Zone Set Temperature Setting
This function is to adjust "set temperature" of individual zone.
Step1. Press "
" or " " to select "Temp".
Step2. By pressing "
", the temperature is increased by 0.5°C or 1°C.
By pressing "
", the temperature is decreased by 0.5°C or 1°C.
NOTE:
The set temperature of the zone can be set to ±3°C of zone base temperature(within the range of upper and
lower limit of the set temperature).
Living
Zone 1 (Spill Zone)
BackSpill zone control on
ON
On#O%%
26
.5
C
Temp
22.5 26.2
Lo4
ON
OO
OFF
OOFF
Living
Zone 1 (Spill Zone)
BackSpill zone control on
ON
On#O%%
26
.5
C
Temp
22.5 26.2
Lo4
Zone average room
temperature
Zone base temperature
Zone set temperature