Remote Controller Manual
Remote Controller manual
Page 1~28
To obtain the best performance and ensure years of trouble free use, please read this instruction manual completely.
MODEL
RC-AGS1EA0E
<0024394D>
-1-
Question and Answer IconNeed help?

Do you have a question about the Hitachi RC-AGS1EA0E and is the answer not in the manual?

Summary

Names and Functions of Remote Controller

Remote Control Button Functions

Describes the various buttons and their primary functions on the remote controller.

Signal Transmission

Explains the indicator for signal transmission and invalid operations on the remote.

Backlight Function

Details the backlight feature of the remote control's LCD screen.

Precautions for Use

Outlines essential safety and handling precautions for the remote controller.

Remote Controller Setup

Battery Installation

Provides step-by-step instructions for installing batteries in the remote controller.

Setting the Clock

Guides users on how to set the clock time on the remote controller.

Various Functions

Auto Restart Control

Explains the automatic restart feature after a power failure.

Auto Mode Operation

Describes how the unit automatically selects operation mode based on room temperature.

Heat Mode Operation

Dry Mode Operation

Cool Mode Operation

Powerful Operation

LeaveHome Operation

Indoor FrostWash Operation

Manual Mode and Precautions

Details manual FrostWash operation, its process, and necessary precautions.

FrostWash and Fan Reverse Auto Modes

Enabling;Disabling Auto Features

Instructions for activating and deactivating FrostWash and Fan Reverse auto modes.

Indoor FrostWash Auto Mode

Explains the conditions and process for automatic indoor FrostWash operation.

Auto Start Conditions

Defines the criteria for the automatic start of indoor FrostWash operation.

Outdoor FrostWash Operation

Auto Mode Process and Conditions

Describes the process and auto start conditions for outdoor FrostWash.

Fan Reverse Auto Mode

Auto Start Conditions

Outlines the conditions under which Fan Reverse auto mode is activated.

Mold Guard Operation

Setting, Cancelling, and Stopping

Covers how to set, cancel, and stop Mold Guard operation.

Operational Notes

Provides important notes regarding Mold Guard operation conditions.

Smart Eco Operation

Starting and Cancelling Modes

Guides on activating and cancelling Smart Eco and Eco+Auto-Off modes.

Cancellation Notes

Notes on conditions that may cancel Smart Eco or Eco+Auto-Off operation.

Smart Eco Logic

Operation Logic and Sensor Notes

Explains the logic for temperature adjustment and sensor accuracy considerations.

Auto-Off Logic and Notes

Details the logic for automatic unit shutoff and related user notes.

Power Safe (Max Current Switching)

Setting and Cancelling Mode

Instructions for setting and cancelling the Power Safe mode to limit current.

Mode Notes

Provides important notes and effects of using the Power Safe mode.

SleepSense Operation

Logic and Operation Details

Explains the logic behind SleepSense and its operational flow.

Starting and Cancelling

Describes how to activate and deactivate the SleepSense function.

Sensor and Cancellation Notes

Notes on sensor accuracy and conditions that cancel SleepSense.

AQtiv-Ion Operation

Starting and Cancelling

Guides on how to start and cancel the AQtiv-Ion function.

Silent Mode

Activating and Deactivating

Instructions for enabling and disabling the Silent Mode for quieter operation.

Mode Notes

Important notes regarding Silent Mode operation and its cancellation.

Fan Mode Operation

Adjusting Upward and Downward Airflow

Adjusting Leftward and Rightward Airflow

Parallel Airflow Adjustment

Describes how to adjust airflow left and right parallelly using the Left/Right button.

Asymmetrical Airflow Adjustment

Explains how to adjust airflow left and right asymmetrically using the Wide Reach button.

Timer Reservation

Off Timer and On Timer Settings

Details the procedures for setting the Off Timer and On Timer functions.

Timer Setting Notes

Provides important notes and limitations regarding timer operations.

airCloud Home Module Initialization

Restoring Factory Settings and Notes

Explains how to restore factory settings for the airCloud module and related notes.

My Mode Programming

Entering and Selecting Settings

Guides on entering My Mode programming and selecting modes, fan speed, temperature, and silent mode.

My Mode Programming Details

Timer Settings and Registration

Details setting On/Off timers within My Mode and registering the program.

Programming Notes

Provides important notes and conditions for My Mode programming.

My Mode Operation Start;Stop

Starting, Stopping, and Notes

Explains how to start, stop, and cancel My Mode operations, with relevant notes.

Operation Mode Lock

Locking and Unlocking Modes

Instructions for locking and unlocking specific operation modes like Heat, Cool, and Dry.

Lock Function Notes

Provides important notes and conditions related to the Operation Mode Lock function.

Resetting Filter Sign

Hardware Reset Function

Overview

This document describes the Hitachi Remote Controller Manual for model RC-AGS1EA0E, detailing its functions, usage features, and maintenance aspects. The remote controller operates the room air conditioner and has a control range of about 7 meters, which may be shorter if indoor lighting is electronically controlled.

Function Description

The remote controller allows users to select various operation modes, adjust temperature, fan speed, and activate specialized functions for enhanced comfort and energy efficiency.

  • On/Off Button: Initiates or stops the air conditioner's operation. A beep confirms the action.
  • Mode Selector Button: Cycles through different operation modes: Heat, Auto, Cool, Dry, and Fan.
    • Auto Mode: The device automatically determines the operation mode (Heat or Cool) based on the current room temperature. If the automatically selected mode is unsatisfactory, users can manually switch to Heat, Dry, Cool, or Fan. Fan speed can be set to Auto, Silent, Low, Medium, High, or Super High. Temperature can be set between 16.0°C and 32.0°C.
    • Heat Mode: Used for heating when the outdoor temperature is under 24°C. The heating function may not work if it's too warm (over 24°C) to protect the device. For reliability, it's recommended to use the device above -15°C outdoor temperature. Fan speed and temperature settings are similar to Auto Mode. Defrosting occurs automatically when frost forms on the outdoor unit's heat exchanger, lasting 5-10 minutes.
    • Dry Mode: Used for dehumidifying when the room temperature is over 16°C; it won't work below 15°C. Fan speed is set to Auto by default, but Silent, Low, or Auto can be selected. Recommended temperature range for dehumidifying is 20.0°C to 26.0°C, with an overall range of 16.0°C to 32.0°C. The device dehumidifies to the preset level if the room temperature is higher than the setting, or slightly lower than the current room temperature if it's lower than the setting.
    • Cool Mode: Used for cooling when the outdoor temperature is between -10°C and 46°C. High indoor humidity (over 80%) may cause dew to form on the indoor unit's air outlet grille. Fan speed and temperature settings are similar to Auto Mode. The cooling function activates when the set temperature is below the current room temperature.
    • Fan Mode: Allows the device to function simply as an air circulator. Fan speed can be set to Silent, Low, Medium, High, or Super High.
  • Temperature Buttons (Up/Down): Adjust the room temperature setting. Holding the button changes the value quicker.
  • Fan Speed Button: Selects the desired fan speed (Auto, Silent, Low, Medium, High, Super High).
  • Powerful Button: Activates maximum power operation for quick cooling or heating in Auto, Heat, Dry, Cool, or Fan modes. This mode lasts for 20 minutes and then reverts to previous settings. It is canceled if SleepSense, Smart Eco, LeaveHome, Silent, or My Mode are active.
  • Silent Button: Changes the fan speed to a silent setting during Auto, Heat, Dry, Cool, or Fan operations. It is canceled if Powerful operation is selected or by pressing Mode, LeaveHome, or My Mode buttons.
  • Up/Down Button: Controls the angle of the horizontal air deflector, allowing it to swing up and down or be set to a desired fixed angle.
  • Left/Right Button: Controls the angle of the vertical air deflector, allowing it to swing left and right parallelly or asymmetrically, or be set to a desired fixed angle.
  • Wide Reach Button: Controls the angle of the vertical air deflector for wide reach, allowing it to swing left and right symmetrically or be set to a desired fixed angle.
  • On Timer Button: Sets the time for the air conditioner to turn ON.
  • Off Timer Button: Sets the time for the air conditioner to turn OFF.
  • SleepSense Button: Utilizes a motion sensor to detect movement, location, and temperature around people to control set temperature and fan speed, aiming for comfortable and energy-saving sleep. It increases temperature in cooling or decreases in heating if no human movement is detected for 1 hour, and adjusts fan speed. It is canceled by Powerful, LeaveHome, Smart Eco, or My Mode buttons.
  • Smart Eco Button: Detects the presence of people in the room. If no one is detected for 20 minutes, the set temperature shifts for energy saving. If no one is detected for 60 minutes, it shifts further. A second press activates "Eco with Auto-Off," which turns off the unit if no activity is detected for 60 minutes. A third press cancels both Eco and Eco with Auto-Off.
  • LeaveHome Button: Prevents the room temperature from falling too low when no one is home. The initial setting is 10.0°C, adjustable between 10.0°C and 16.0°C. Fan speed and deflector position cannot be changed in this mode. It disables Powerful, SleepSense, Smart Eco, Timer, Silent, and My Mode operations.
  • AQtiv-Ion Button: Activates the AQtiv-Ion operation during Heat, Auto, Cool, Dry, or Fan modes.
  • My Mode Button: Allows users to program up to three personalized comfort settings, including mode, temperature, fan speed, and timer/silent settings.
  • Power Safe (Max Current Switching): Limits the maximum current drawn by the air conditioner to prevent breaker trips. This function reduces compressor speed, which may result in less cooling or heating performance. It is recommended to use Auto Fan speed in this mode.
  • Mold Guard Operation: After cooling or dehumidifying operation, the indoor unit's fan dries the unit by heating or fan mode for about 100 minutes to suppress mold generation. It does not remove or sterilize mold. It activates after more than 10 minutes of cooling/drying and stopping the unit.
  • Operation Mode Lock: Allows locking the remote controller to specific modes (Heat, Cool, Dry, including Fan Mode) to prevent accidental changes.

Usage Features

  • Backlight Function: The LCD panel lights up for approximately 10 seconds when any key is pressed, aiding visibility in the dark.
  • Battery Installation: Requires two new batteries, ensuring correct polarity. Old and new batteries, or different types, should not be mixed. Batteries should be removed if the remote controller is not used for 2-3 months.
  • Clock Setting: Users can set the current time using the Temperature Up/Down buttons after pressing and holding the Timer ON or Timer OFF button for 5 seconds.
  • Auto Restart Control: In case of a power failure, the unit automatically restarts with previous operation mode and airflow direction settings once power is restored. This feature is not available when a timer is set.
  • FrostWash (Auto Mode): Automatically cleans the indoor unit's heat exchanger by freezing and thawing. It activates after 42 accumulated operating hours, or if the unit stops after more than 30 minutes of operation, or if a human sensor detects presence/absence for specific durations. It can be enabled/disabled by pressing Temperature Up/Down and FrostWash buttons simultaneously for 3 seconds in OFF mode.
  • Fan Reverse (Auto Mode): Rotates the outdoor unit's fan in reverse direction when stopped to blow away dust from the outdoor heat exchanger. This function activates automatically.
  • Initialization of Built-in airCloud Home Module: Allows resetting the internal settings to factory defaults. This requires pressing the Mode and On Timer buttons simultaneously for 3 seconds in OFF mode.

Maintenance Features

  • Filter Sign Reset Button: Resets the filter sign on the indoor unit after the air filter has been cleaned. This button is active only in OFF mode.
  • FrostWash (Manual Mode): Allows users to manually initiate the FrostWash cleaning cycle when the unit is off by pressing the FrostWash button. This process takes up to 120 minutes.
  • Reset Function (Hardware Reset): In case of display issues or unresponsive keys, pressing the Reset button restores the remote controller's hardware to default settings. A pointed item like a pen is needed to press the button. All settings except some special activated functions will be reset.

Precautions for Use

  • Avoid direct sunlight and high temperatures for the remote controller.
  • Protect the remote controller from drops and water.
  • If any function button is pressed during operation, the air conditioner may pause for about 3 minutes for protection before resuming.
  • During FrostWash, avoid opening windows/doors, as water may drip. Do not open or remove the front panel. Hissing or squeaking noises may occur. The function is not effective if the air conditioner is continuously running.
  • Do not operate the air deflector manually.
  • In Cooling operation, avoid keeping the horizontal or vertical air deflector swinging for extended periods to prevent dew formation and water drops.
  • During Mold Guard operation, room temperature or humidity may rise.
  • Smart Eco's sensor accuracy may be affected by low activity levels, blocked human bodies, high indoor temperatures, thick clothing, or swinging curtains/plant leaves.
  • For Smart Eco with Auto-Off, if infants or sick persons are present, it's recommended not to use Auto-Off, as the unit might stop operation.
  • Power Safe mode may reduce cooling/heating performance.
  • Timer settings cannot be changed if On Timer or Off Timer are already set.
  • Operation Mode Lock will not activate if Timer reservations or My Mode are active.

Hitachi RC-AGS1EA0E Specifications

General IconGeneral
BrandHitachi
ModelRC-AGS1EA0E
CategoryRemote Control
Power SourceBattery
Battery TypeAAA
Battery Quantity2
Compatible DevicesHitachi Air Conditioner

Related product manuals