CP-X2511N(C15I-25N2) / CP-X3011N(C15I-30N2) / CP-X4011N(C15I-40N2) / CP-X2011N(C15-20N2) / ED-X45N(C15-20N2)
Wiring diagram 3
Wiring of power supply block 3
(1) Wire CNTS, CNLAP and CNGD1
(2) Secure CNTS and CNBAR
Area of Importance
Confirm that the CNBAR is passing through the opening
area of the insulating sheet and that it is not loosened here.
This work is important to keep the CNBAR apart from the
primary parts.
Bend the CNPFC to the inside of the power
supply block so that he CNPFC will not touch
the metallic casing (power shield metal)
attached in later process.
Do not let the CNPFC and the ferrite core
touch and press the electrolytic capacitor.
View from front side
View from rear side
CNBAR
CNPFC
Area of Importance
To maintain the clearance distance for insulation, make wiring so that any cables
are not loosened inside the power supply block.
Make sure not to pinch the
CNPW wires when assembling
the power supply block.
Area of Importance
Wire the CNLAP without loosened here
in order to prevent it from touching to
the transfer of the power unit circuit.
CNBAR
CNPW
CNTS
CNGD1
Pass the CNTS through this hook.Pass the CNTS and the CNPW
through this hole.
Pass the CNBAR and the
CNGD1 through the hole here.
Pass the CNTS and the
CNBAR through this hole
to secure them. Put the
CNBAR prior to CNTS so
that the CNBAR will not
come off.
Pass the hole of the insulating sheet.
CNPW
Ballast Power Unit
Circuit
Power
Unit
Power Supply Block