43
CP-X2520 ( M2-25ED ) / CP-X3020 ( M2-30ED )
Notice
 Detach and attach the upper case.
Follow the procedure below to detach and attach the upper case.
When disassembling
CAUTION
The lamp door must be removed before the upper case when disassembling the machine. If the upper 
case is detached with the lamp door installed, the MAIN board might be damaged.
a. Remove the Lamp door.
Loosen this screw
b. Remove 7 screws on the bottom and 3 screws on the rear to detach the upper case.
M2.6x16 screw (2pcs)
M2.6x8 screw (1pc)
CAUTION
This is not a screw hole. Do NOT insert a screw or screwdriver into it to avoid damaging the inside.
T2.6x12 screw (7pcs)
Lamp door