Maintenance
Consumption of the battery makes the internal clock not to work correctly. When the internal clock
is wrong or it has stopped, please replace the battery according to the following procedures.
Replacing the internal clock battery
1.
Turn the projector off, and unplug the power cord. Allow the
projector to cool sufciently.
2.
After making sure that the projector has cooled adequately,
pull the SD card slot cover forward, pushing slightly its edge
up, and remove it from the projector.
3.
Remove the battery case.
Hold the battery case gutter by nger nail or other thing and
pull out the battery case slowly from the battery slot.
While the projector is installed upside down, such as a
ceiling mount, please remember the battery will drop down
as soon as pulling the battery case out.
4.
Take the old battery out from the battery case.
5.
Replace a new battery.
Replace battery with HITACHI MAXELL, Part No.CR2032
only. Use of another battery may present a risk of re or
explosion.
Put a new battery into battery case. Please make sure that
the + is facing upward. Insert the battery case slowly into the
battery slot until you hear the snap.
6.
Close the slot cover.
Replace the SD card slot cover by reversing the procedure
used when removing the cover.
• The internal clock’s time will be reset when the battery is removed.
Please recongure the time via the menu or a web browser after replacing the battery.
(
Date/Time Settings in the User's Manual (detailed) - Network Guide)
NOTE
►Always handle the batteries with care and use them only as directed.
Battery may explode if mistreated. Do not recharge, disassemble or dispose of in re.
And also improper use may result in cracking or leakage, which could result in re, injury
and/or pollution of the surrounding environment.
• Be sure to use only the batteries specied.
• Make sure the plus and minus terminals are correctly aligned when loading a battery.
• Keep a battery away from children and pets. If swallowed consult a physician
immediately for emergency treatment.
• Do not short circuit or solder a battery.
• Do not allow a battery in a re or water. Keep batteries in a dark, cool and dry place.
• If you observe battery leakage, wipe out the leakage and then replace a battery.
If the leakage adheres to your body or clothes, rinse well with water immediately.
• Obey the local laws on disposing the battery.
WARNING
Battery Slot
Battery Case
Battery
Battery
Case
Battery
Case
Battery (+)
Battery (-)
SD card slot cover

Other manuals for Hitachi CP-X417

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hitachi CP-X417 and is the answer not in the manual?

Hitachi CP-X417 Specifications

General IconGeneral
BrandHitachi
ModelCP-X417
CategoryProjector
LanguageEnglish

Related product manuals