ABOUT THE SYSTEM SYSTEM FEATURES
1-4
SKU information
2.5" All Flash SKU
System rating
800W AC PSU:
100-115V/120V/200-240Vac, 50/60Hz, 7.4A/7.4A/4.5A, or 240Vdc, 3.5A (per
PSU inlet)
1200W AC PSU:
100-120/200-240Vac, 50/60Hz, 8/6A or 240Vdc, 5A (per PSU inlet)
1600W PSU Full range:
100-120/200-240Vac, 50/60Hz, 10/8A or 240Vdc, 7A (per PSU inlet)
1600W PSU High Line only:
200-240Vac, 50/60Hz, 8A or 240Vdc, 8A (per PSU inlet)
1200W DC PSU:
- 48Vdc, 25A or +48Vdc, 25A (per PSU inlet)
- 39V --72V, 30A or +39V - +72V , 30A (per PSU inlet)
1600W DC PSU:
- 48Vdc, 40A or +48Vdc, 40A (per PSU inlet)
- 39V - -72V, 40A or +39V - +72V , 40A (per PSU inlet)
Fan
(8) dual rotor fans (15+1 redundant)*
*Hot-swap feature will be available only while the optional Cable Management
Arm (CMA) is installed.
System management IPMI v2.0 Compliant, on board "KVM over IP" support
Operating environment
Operating temperature: 5°C to 40°C (41°F to 104°F)
Non-operating temperature: -40°C to 70°C (-40°F to 158°F)
Operating relative humidity: 50% to 85%RH
Non-operating relative humidity: 20% to 95%RH
Table 1: System Specifications (Continued)
SPECIFICATIONS DESCRIPTION