State Percentage
Non-operating 8 to 90
Transport, storage (%) 5 to 95
Maximum wet bulb temperature (°C) 29 (non-condensing)
Vibration
State
m/s
2
Operating 2.5 or less
Within 5 seconds (resonance point: 10 Hz or
less)
Non-operating 5.0 or less at 5 Hz to 300 Hz (no damage to
product)
9.8 (1.0 G)
Within 5 seconds (resonance point: 10 Hz or
less)
Transport (packed) 5.0 or less
Impact
State m/s
2
Operating 20 or less
(10 ms, half sine wave)
Non-operating 50 or less
(10 ms, half sine wave)
Transport (packed) 80 or less
Altitude
State
Controller FMD drive
Operating (m)
3,000
(Environmental
temperature:
10°C to 32°C)
900
(Environmental
temperature:
10°C to 40°C)
3,000 (Environmental temperature 10°C to 32°C)
OR
900 (Environmental temperature: 10°C to 35°C) when
DKC-F710I-1R6FM or DKC-F710I-3R2FM drive is installed.
Operating (m)
3,000
(Environmental
temperature:
10°C to 32°C)
3,000 (Environmental temperature: 10°C to 32°C)
OR
116 Storage system specifications