Item Controller
SFF, LFF, dense
intermix drive trays
(range for setup)
RAID 6 N/A 6D+2P, 12D+2P, 14D
+2P
Item Controller
FMD drive tray (range
for setup)
RAID level N/A SAS, SAS 7.2 krpm,
flash drives mounted:
0, 1, 5, 6, 1+0 (DBW
supports SAS 7.2k
drives)
RAID configuration
(unit of addition)
RAID 1 N/A 2D+2D, 4D+4D
RAID 5 N/A 3D+1P, 4D+1P, 6D+1P,
7D+1P
RAID 6 N/A 6D+2P, 12D+2P, 14D
+2P
Note: Although certain RAID configurations support redundancy in the event
of a drive failure, best practices dictate that you back up data on a regular
basis.
iSCSI specifications
Item
Specification Comments
iSCSI target function Supported N/A
iSCSI target function Supported TrueCopy® only
iSCSI ports 2 per interface board
VSP Gx00 models: Maximum 32
per iSCSI system
Connection methods Direct and switch connections
Host connections 255 (maximum per iSCSI port) With Linux software initiator,
the maximum number
decreases.
Path failover HDLM
1
Supports Microsoft MPIO (Multi
Path I/O)
Link 10 Gbps SFP+ N/A
Transfer speed 10 Gbps N/A
Connector type LC N/A
Storage system specifications 119
Hitachi Virtual Storage Platform G800 Hardware Reference Guide