raidcom add lun
Error message
Executing/
Async
Error code
Description
SSB1 SSB2
CMDRJE Executing B958 0639 The command device cannot be operated because
it is used at the local CCI.
CMDRJE Executing B958 064A A command device cannot be set because LDEV is
other than the OPEN volume.
CMDRJE Executing B958 065D The specified LDEV is not installed.
CMDRJE Executing B958 0679 A command device cannot be set because LDEV is
the virtual volume of Thin Image or Copy-on-Write
Snapshot.
CMDRJE Executing B958 06C0 The specified LDEV is being used as a volume of a
GAD pair.
CMDRJE Executing B958 06C1 The specified LDEV is used as a quorum disk.
CMDRJE Executing B958 06C2 The specified LDEV is used for a TrueCopy pair or a
Universal Replicator pair.
CMDRJE Executing B958 0927 The command cannot be operated because the
virtual LDEV is not defined yet.
CMDRJE Executing B958 0944 The value of LUN exceeds the maximum.
CMDRJE Executing B958 0945 The value of LDEV exceeds the maximum.
CMDRJE Executing B958 0947 Another LDEV is already mapped to the specified
LUN.
CMDRJE Executing B958 0956 The value of Host group ID exceeds the maximum.
CMDRJE Executing B958 0957 The program product is not installed.
CMDRJE Executing B958 0959 The specified host group is not installed.
CMDRJE Executing B958 095D An invalid LDEV exists in the specified LDEVs.
CMDRJE Executing B958 098C The multiple LDEV cannot be specified.
CMDRJE Executing B958 098D When the host mode option 60 is set, the LU path
of LUN0 cannot be set or released.
CMDRJE Executing B958 0994 An invalid LDEV exists in the specified LDEVs.
CMDRJE Executing B958 0996 The LU path cannot be added because the virtual
LDEV ID of the specified volume was deleted.
CMDRJE Executing B958 099C The number of paths exceeds the maximum.
CMDRJE Executing B958 099D Only one path is set for NAS Platform (User LU).
CMDRJE Executing B958 099E Both the port number and the host group ID are
specified.
CMDRJE Executing B958 099F The specified port is not mounted.
CMDRJE Executing B958 09F8 The LU path cannot be set because the specified
LDEV is being deleted.
Troubleshooting
9-71
Command Control Interface User and Reference Guide