raidcom delete snapshot
Error message
Executing/
Async
Error code
Description
SSB1 SSB2
The control table for Thin Image is depleted.
CMDRJE Executing 2E11 2206 You do not have the operation authority to operate
the target resource group.
Specify the resource group that is allocated to the
user group as the operation target, or set the
operation authority to the user group in order to
operate the target resource group.
CMDRJE Executing 2E11 8003 The operation cannot be performed because
power-off is in progress.
CMDRJE Executing 2E11 9704 The operation cannot be performed because a pair
exists under the specified pair.
CMDRJE Executing 2E11 9706 The operation cannot be performed because the
specified volume is not a root volume of a pair with
the cascade or clone attribute, or the volume is an
S-VOL in another snapshot tree.
CMDRJE Executing 2E20 0000 The specified LDEV is not defined.
CMDRJE Executing 2E20 0008 The command ends abnormally because an
unmounted volume is specified as the P-VOL of a
Thin Image pair or a Copy-on-Write Snapshot pair.
CMDRJE Executing 2E20 0009 The command ends abnormally because the
blocked volume is specified as the P-VOL of a Thin
Image pair or a Copy-on-Write Snapshot pair.
CMDRJE Executing 2E21 8107 The command ends abnormally because the shared
memory (FC, TPF, or Extension2) is not added for
necessary capacity or maintenance work is being
performed.
CMDRJE Executing 2E21 8108 The shared memory for Thin Image or Copy-on-
Write Snapshot is not installed.
CMDRJE Executing 2E21 9306 The virutal LDEV ID for a virtual storage machine is
not defined on the specified LDEV.
CMDRJE Executing 2E21 930A The virtual storage machine with the specified
serial number is not found.
CMDRJE Executing 2EC6 FEEC An internal error occurred. Call Hitachi Data
Systems customer support.
CMDRJE Executing B980 B903 The command was rejected because the selected
resource belongs to NAS_Platform_System_RSG.
Troubleshooting
9-101
Command Control Interface User and Reference Guide