raidcom delete rcu_path
Error message
Executing/
Async
Error code
Description
SSB1 SSB2
CMDRJE
Get Command
Status
Executing/
Async
2E00 7100 The CU number is out of effective range.
CMDRJE
Get Command
Status
Executing/
Async
2E00 8400 The value of the specified port is invalid.
Get Command
Status
Async 2E10 3101 Failed to establish a path or the deletion operation.
The following factor can be thought.
Input parameter is invalid.
Port status or the MP Blade status is in the
state of abnormal.
Cable is not connected correctly.
Port is specified incorrectly.
Get Command
Status
Async 2E11 8004 The operation cannot be performed because the
microcode is being changed.
CMDRJE Executing 2E11 9400 The command cannot be accepted. After a while,
execute the same command.
Get Command
Status
Async 2E20 3001 A logical path cannot be deleted because the
specified RCU is not registered.
Get Command
Status
Async 2E21 7101 The specified CU number is not defined, or an
LDEV is not defined under the CU number.
Get Command
Status
Async 2E23 3101 The operation cannot be performed because the
number of paths becomes less than the least path
number.
CMDRJE Executing 2E30 840A The port attribute is not Initiator (MCU).
CMDRJE Executing 2E30 840E The command cannot be executed with the
specified port attribute.
Get Command
Status
Async 2E31 3001 The command cannot be executed because the
RCU identification code of a path is invalid.
Get Command
Status
Async 2E31 3101 The command cannot be executed because the
serial number is not unified in the specified path.
CMDRJE Executing 2ED6 00EE The command cannot be accepted because the
DKC is busy. After a while, execute the same
command.
Get Command
Status
Async 2ED6 3005 An internal error occurred.
Call Hitachi Data Systems customer support.
CMDRJE Executing 2EF3 3002 The specified parameter is invalid. Check the
Command Control Interface Command Reference.
CMDRJE Executing B980 B901 The command was rejected because the specified
port is for NAS Platform (System LU).