raidcom delete rcu_path
Error message
Executing/
Async
Error code
Description
SSB1 SSB2
CMDRJE Executing B980 B902 The command was rejected because the specified
port is for NAS Platform (User LU).
Table 9-59 SSB codes returned by raidcom add rcu_path
raidcom add rcu_path
Error message
Executing/
Async
Error code
Description
SSB1 SSB2
CMDRJE Executing 2E00 3001 CU# of RCU exceeds the effective value.
CMDRJE Executing 2E00 3005 Invalid product ID or path registration ID.
Get Command
Status
Async 2E00 3008 The command cannot be executed because the
parameter of the specified RCU is invalid.
Get Command
Status
Async 2E00 3009 The command cannot be executed because all the
CU numbers in the RCU is not unified at the path
that is specified creation or deletion.
CMDRJE Executing 2E00 3200 The value of port # on the side of RCU is invalid.
CMDRJE
Get Command
Status
Executing
/Async
2E00 7100 The CU number is out of effective range.
CMDRJE
Get Command
Status
Executing/
Async
2E00 8400 The value of the specified port is invalid.
Get Command
Status
Async 2E10 3101 Failed to establish a path or the deletion operation.
The following factor can be thought.
• Input parameter is invalid.
• Port status or the MP Blade status is in the
state of abnormal.
• Cable is not connected correctly.
• Port is specified incorrectly.
Get Command
Status
Async 2E11 8004 The operation cannot be performed because the
microcode is being changed.
CMDRJE Executing 2E11 9400 The command cannot be accepted. After a while,
execute the same command.
Get Command
Status
Async 2E20 3000 The serial number, the product ID, or the SSID of
the target storage system is incorrect.
Get Command
Status
Async 2E20 3001 A logical path cannot be added because the
specified RCU is not registered.
Get Command
Status
Async 2E21 7101 The specified CU number is not defined, or an
LDEV is not defined under the CU number.
9-120
Troubleshooting
Command Control Interface User and Reference Guide