raidcom add rcu_path
Error message
Executing/
Async
Error code
Description
SSB1 SSB2
Get Command
Status
Async 2E23 3100 An RCU path cannot be added because the number
of valid paths exceeds the maximum.
Get Command
Status
Async 2E23 3101 The operation cannot be performed because the
number of paths becomes less than the least path
number.
CMDRJE Executing 2E30 840A The port attribute is not Initiator (MCU).
CMDRJE Executing 2E30 840E The command cannot be executed with the
specified port attribute.
Get Command
Status
Async 2E31 3001 The command cannot be executed because the
RCU identification code of a path is invalid.
Get Command
Status
Async 2E31 3101 The command cannot be executed because the
serial number is not unified in the specified path.
CMDRJE Executing 2ED6 00EE The command cannot be accepted because the
DKC is busy. After a while, execute the same
command.
Get Command
Status
Async 2ED6 3005 An internal error occurred.
Call Hitachi Data Systems customer support.
CMDRJE Executing 2ED6 3300 The value of SSID on the remote storage system is
invalid.
CMDRJE Executing 2EF3 3002 The specified parameter is invalid. Check the
Command Control Interface Command Reference.
CMDRJE Executing B980 B901 The command was rejected because the specified
port is for NAS Platform (System LU).
CMDRJE Executing B980 B902 The command was rejected because the specified
port is for NAS Platform (User LU).
Table 9-60 SSB codes returned by raidcom delete rcu
raidcom delete rcu
Error message
Executing/
Async
Error code
Description
SSB1 SSB2
CMDRJE Executing 2E00 3001 CU# on the RCU exceeds the effective range.
CMDRJE Executing 2E00 3005 Invalid product ID or path registration ID.
Get Command
Status
Async 2E00 3008 The command cannot be executed because the
parameter of the specified RCU is invalid.
CMDRJE Executing 2E00 3200 The value of the specified port# on the RCU side is
invalid.
Get Command
Status
Async 2E00 7100 The CU number is out of effective range.