raidcom add rcu
Error message
Executing/
Async
Error code
Description
SSB1 SSB2
Get Command
Status
Async 2E00 3009 The command cannot be executed because all the
CU numbers in the RCU is not unified at the path
that is specified creation or deletion.
CMDRJE Executing 2E00 3200 The value of port# on the side of RCU is invalid.
CMDRJE
Get Command
Status
Executing/
Async
2E00 7100 The CU number is out of effective range.
CMDRJE
Get Command
Status
Executing/
Async
2E00 8400 The value of the specified port is invalid.
Get Command
Status
Async 2E10 3101 Failed to establish a path or the deletion operation.
The following factor can be thought.
Input parameter is invalid.
Port status or the MP Blade status is in the
state of abnormal.
Cable is not connected correctly.
Port is specified incorrectly.
Get Command
Status
Async 2E11 8004 The operation cannot be performed because the
microcode is being changed.
CMDRJE Executing 2E11 9400 The command cannot be accepted. After a while,
execute the same command.
Get Command
Status
Async 2E20 3000 The serial number, the product ID, or the SSID of
the target storage system is incorrect.
Get Command
Status
Async 2E21 7101 The specified CU number is not defined, or an
LDEV is not defined under the CU number.
Get Command
Status
Async 2E22 3001 The specified RCU is already registered to another
product ID.
Get Command
Status
Async 2E22 3002 The operation cannot be performed due to one of
the following reasons:
The number of RCUs registered in MCU or RCU
is more than four.
The number of RCUs registered in the system
is more than 64 in the case of specifying the
cu free.
Get Command
Status
Async 2E22 3300 The specified SSID is already registered to another
RCU.
Get Command
Status
Async 2E23 3000 The specified RCU is cannot be registered because
there is no free RCU.
Get Command
Status
Async 2E23 3101 The operation cannot be performed because the
number of paths becomes less than the least path
number.