Table 9-85 SSB codes returned by raidcom modify port -selective_ack_mode
raidcom modify port -selective_ack_mode
Error message
Executing/
Async
Error code
Description
SSB1 SSB2
CMDRJE Executing B955 1039 The command device being used at the local CCI
exists under the port.
CMDRJE Executing B955 120E The command cannot be executed because the
iSCSI virtual port mode is ON.
Table 9-86 SSB codes returned by raidcom modify port -tcp_port
raidcom modify port -tcp_port
Error message
Executing/
Async
Error code
Description
SSB1 SSB2
CMDRJE Executing B955 1039 The command device being used at the local CCI
exists under the port.
CMDRJE Executing B955 120E The command cannot be executed because the
iSCSI virtual port mode is ON.
Table 9-87 SSB codes returned by raidcom modify port -add_vlan_id
raidcom modify port -add_vlan_id
Error message
Executing/
Async
Error code
Description
SSB1 SSB2
CMDRJE Executing B955 1039 The command device being used at the local CCI
exists under the port.
CMDRJE Executing B955 10B2 The invalid value is specified for the VLAN ID.
CMDRJE Executing B955 10CB The number of VLANs exceeds the maximum.
CMDRJE Executing B955 120E The command cannot be executed because the
iSCSI virtual port mode is ON.
Table 9-88 SSB codes returned by raidcom modify port -delete_vlan_id
raidcom modify port -delete_vlan_id
Error message
Executing/
Async
Error code
Description
SSB1 SSB2
CMDRJE Executing B955 1039 The command device being used at the local CCI
exists under the port.
CMDRJE Executing B955 10B2 The invalid value is specified for the VLAN ID.
Troubleshooting
9-139
Command Control Interface User and Reference Guide