Table 9-92 SSB codes returned by raidcom modify port -t10pi
raidcom modify port -t10pi
Error message
Executing/
Async
Error code
Description
SSB1 SSB2
CMDRJE
Get Command
Status
Executing
Async
2E00 8400 The value of the specified port is invalid.
CMDRJE
Get Command
Status
Executing
Async
2E00 8404 The channel board of the object is not supported.
Get Command
Status
Async 2E10 8000 The operation cannot be performed because
Storage Navigator or Device Manager - Storage
Navigator is in progress, another application is in
progress on the SVP, or the configuration is being
changed. Wait a while, and then retry the
operation.
CMDRJE
Get Command
Status
Executing
Async
2E10 8400 The specified port is blocked.
CMDRJE Executing 2E11 9400 The command cannot be accepted. After a while,
execute the same command.
CMDRJE
Get Command
Status
Executing
Async
2E20 8400 The specified port is not installed.
Get Command
Status
Executing
Async
2E30 840F LU path of the specified port or LU path of the port
in the same group is defined, the T10 PI attribute
of the port cannot be changed.
CMDRJE Executing 2E3F 8000 The specified operation is not supported in the
current microcode version.
CMDRJE
Get Command
Status
Executing
Async
2ED0 FEEC An internal error occurred.
Table 9-93 SSB codes returned by raidcom modify port -add_iscsi_virtual_port
raidcom modify port -add_iscsi_virtual_port
Error message
Executing/
Async
Error code
Description
SSB1 SSB2
CMDRJE Executing B955 1039 The command device being used at the local CCI
exists under the port.
CMDRJE Executing B955 10B0 The invalid value is specified for the Ethernet MTU
size.
CMDRJE Executing B955 10B2 The invalid value is specified for the VLAN ID.
Troubleshooting
9-141
Command Control Interface User and Reference Guide