Removingthehousingcover
There are several ways which depend on the scale of the housing cover.
scale (small) : (200V class ) 0.2kW, 0.4kW, 0.75kW
scale (middle): (200V class ) 1.5kW, 2.2kW, 3.7kW
(400V class ) 0.4kW 3.7kW
Scale(small)
1.Remove the monitor cover, front cover and rear cover.
When removing the monitor cover, please remove the communication cable
from the front cover side.
2.Insert the minus screw driver between the cooling fin and the housing, and unlock the tabs
(4 points at the left and right side) .
3. Remove the housing.
housing
monitor cover
front cover
rear cover
tab1
tab2
tab3
tab4