46
Confidential to Customer
4.19 Main motor removal
Prepare the additional 2×M16 eyebolts for this procedure.
4.19.1 Main motor removing for the fixed speed type.
55kW Motor Weight : 864 lbs (392 kg),
75kW Motor Weight : 1186 lbs (538 kg)
With hanging the motor by using a motor eyebolt, remove the 8×M16-45 bolt for the gear casing and shaft seal
cover, and remove the 2×M16-80 for the motor and base plate
② Screw the 2×M16 stud bolt into the removal holes, and remove the shaft seal cover from the gear casing using the
2×M16-80 bolt. 2×M16-80 bolt shall be tightened slowly and evenly.
When the shaft seal cover is removed from the gear casing, change the 2×M16-80 bolt to 2×M16 eyebolts. Hang the
motor by three eyebolts so that motor can keep the horizontal situation.
Move the motor for ODE side until bull gear can be seen.
Remove the motor. If you want to remove the motor for horizontal direction, lift the motor by crane so that shaft seal
cover does not hit the motor base.
Eyebolt
Shaft Seal Cover
Gear Casing
8×M16-45 bolt
2×M16-80 bolt
2×M16 stud bolt
2×M16-80 bolt
Gear casing
Gear casing
2×M16 eyebolts
2×M16-80 bolt
(Hang the motor by three eyebolts)
Gear casing
Bull gear
Shaft seal cover
Motor base