5. Function Menu Screen Display
28
A16381TMEU
5.7 Autoboost Setting
The function is used to increase the cooling and heating capacity in 30 minutes once the operation starts.
This function is only available when the operation mode is Cool or Heat.
The unit starts each time in quick mode until the setting is canceled.
NOTES:
Autoboost cannot be set when the outdoor unit does not support this function.
Autoboost cannot be used if Power Savings is not supported.
When this function is activated while mode is "Cool", fan speed changes and is locked as "Auto" for 30
minutes at the longest regardless of the current setting. While in this operation (fan speed "Auto"), fan level
may drop as low as "Low" when the room temperature gets close to the setting temperature. The operation
starts regardless of the fan speed.
1. Set the autoboost
Step1. Select "Autoboost" on the "Function Menu" screen and
press "OK".
Step2. Press " " or " "
the selected items changes as follows:
"Not Set"
"Cool"
"Heat"
"Cool + Heat".

settings.
Press " " to return to the "Function Menu" screen.
Power Consumption Display
Autoboost
Comfort Setting
Motion Sensor Setting
Setback Setting
Function Menu
OK
Select Back
(Mon) 16:30
Autoboost
Cool
Heat
Cool + Heat
Not Set
OK
Select Back