8.4 REFRIGERANT CHARGE
! CAUTION
• Do not charge OXYGEN, ACETYLENE, or other ammable and
poisonousgasesintotherefrigerantbecauseanexplosioncanoccur.
Itisrecommended thatoxygenfree nitrogen becharged for these
typesoftestscyclewhenperformingaleakagetestoranairtighttest.
Thesetypesofgasesareextremelydangerous,
• Insulate the unions and are-nuts at the piping connection part
completely.
• Insulate the liquid piping completely to avoid a decrease of
performance;ifnot,itwillcausesweatingonthesurfaceofthepipe.
• Charge refrigerant correctly. Overcharging or insufcient charging
couldcauseacompressorfailure.
• Checkforrefrigerantleakageindetail.Ifalargerefrigerantleakage
occurred, it would cause difculty with breathing or harmful gases
wouldoccurifarewerebeingusedintheroom.
• Ifthearenutistightenedtoohard,thearenutmaycrackaftera
longtimeandcauserefrigerantleakage.
8.5 REFRIGERANT CHARGING QUANTITY
In case of the actual piping length is more than the specied length, the additional refrigerant quantity should be charged according
to the table below:
Outdoor unit refrigerant
charge (kg)
Chargeless length (m) Additional refrigerant charge (P) (g/m)
Max additional
charge (kg)
1 IU 2 IU 1 IU 2 IU
RAS-2HVNP1 1.6 30 0 30 30 1.5
RAS-2.5HVNP1 1.6 30 0 30 24 1.2
RAS-3HVNC1
1.9 20
20
40 40
1.2
RAS-3HVRNS3 1.9 20 20 40 40 1.2
1 Determine an additional refrigerant quantity according to the
following procedure, and charge it into the system.
2 Record the additional refrigerant quantity to facilitate service
activities thereafter.
! CAUTION
• When charging refrigerant accurately measure refrigerant to be
charged.
• Overchargingorunderchargingofrefrigerantcancausecompressor
trouble.
• Incaseofactualpipinglengthlessthan5m,consultyourdistributor.
• Charge refrigerant correctly. Overcharging or insufcient charging
couldcauseacompressorfailure.
8.6 CAUTION OF THE PRESSURE BY CHECK JOINT
When the pressure is measured, use the check joint of gas stop
valve, and use the check joint of liquid piping in the gure below.
At that time, connect the pressure gauge according to the
following table because of high pressure side and low pressure
side changes by operation mode.
Cooling
Operation
Heating
Operation
Check Joint for Gas Stop Valve Low Pressure High Pressure
Check Joint for Liquid Stop Valve
Exclussive for Vacuum Pump
and Refrigerant Charge
? NOTE
Becarefulthatrefrigerantandoildonotsplashtotheelectricalpartsat
removingthechargehoses.
Stop valve (liquid)
Stop valve (gas)
Setting of Pipe Length DSW
DSW2 setting will be required only when the refrigerant pipe
length is shorter than 5 m or longer than 30 m. Pipe length
setting shall be performed as shown below.
(The side in the table below shows the DSW location)
DSW2 on Outdoor PCB1
Factory setting Pipe Length ≤ 5m Pipe Length ≥ 30m
REFRIGERANT PIPING & REFRIGERANT CHARGE