8. Troubleshooting
281
SMGB0079 rev.0 - 01/2013
8
Transistor module checking procedure
Outer Appearance and Internal Circuit of Transistor Module
1. Drive circuit.
2. Overheating protection circuit.
3. Sensor.
1
1
1
1
1
1
1
2
3
Procedure:
Remove all the terminals of the transistor module before check. If items [1] [4] are performed and the results are satis-
factory, the transistor module is normal.
Measure it under 1kΩ range of a tester.
N O T E
DONOTuseadigitaltester.
1 By touching the + side of the tester to the P terminal of transistor
module and the - side of tester to U, V and W of transistor mo-
dule, measure the resistance. If all the resistances are from 1 to
5kΩ, it is normal.
2 By touching the - side of the tester to the P terminal of transistor
module and the + side of tester to U, V and W of transistor mo-
dule, measure the resistance. If all the resistances are greater
than 100kΩ, it is normal.
3 By touching the - side of the tester to the N terminal of transistor
module and the + side of tester to U, V and W of transistor mo-
dule, measure the resistance. If all the resistances are from 1 to
5kΩ, it is normal.
4 By touching the + side of the tester to the N terminal of transistor
module and the - side of tester to U, V and W of transistor modu-
le, measure the resistance. If all the resistances are greater than
100kΩ, it is normal.