10 Servicing
352
SMGB0077 rev.0 - 01/2013
10.6.6 Removal of the oat switch
Part
1 Float switch position
N O T E
Todisconnectandremovetheoatswitch,previouslyseethe
chapter corresponding to the wiring diagrams in this Manual.
Remove the drain pump support screws and remove it.
Loosen the screws securing the oat switch to the support.
Loosen the resin nut securing the oat switch and remove it.
N O T E
The torque value of the resin nut is 0.3 - 0.4 Nm. If the torque
value is higher, the nut will be damaged.
Part
1 Float switch
10.6.7 Removal of the air lter
Part
1 Air lter
2 Screws
3 Air lter xture bar