REMOTE CONTROL
OPERATION PROCEDURE FOR SWING LOUVER ADJUSMEN
Swing 
louver 
setting
1.  When the SWING LOUVER switch is pressed, the swing louver starts its 
operation. The range of the swinging angle is approximately 70° from the 
horizontal position to the downward position. When the “          ” mark is 
moving, it indicates conitnous operation of the louver.
2.  When the swinging operation of the louver is not required, press the 
SWING LOUVER switch again. The louver is stopped at an angle indicated 
by the direction of this mark “          ”.
3.  Discharge air angle is fi xed (at 20° for RCI series and 40° for RCD series) 
during start-up of heating operation and defrosting operation when 
thermostat is ON. When the outlet air temperature reaches above 30 °C, 
swinging of louvers is started.
Fixing of 
Louver
1.  In the case of cooling and dry operation, discharge air angle can be 
changed at 5 positions. In the case of heating operation, it can be changed 
at 7 positions
2.  To fi x the louver position, fi rst press the SWING LOUVER switch to start 
the louver swinging, and then press the SWING LOUVER switch again 
when the louver reaches the required position.
3.  Discharge air angle is fi xed (at 20° for RCI series and 40° for RCD series) 
during start-up of heating operation and defrosting operation when 
thermostat is ON. When the outlet air temperature reaches above 30 °C, 
swinging of louvers is started.
4.  When the louvers are fi xed at an angle 55° RCI, 65° RCD or 70° both 
during heating operation and the operation mode is changed to cooling 
operation, louvers will be automatically fi xed at an angle of 45° RCI, 60° 
RCD.
NOTE:
There is a time lag between the actual angle of the louver and 
the liquid crystal indication. When the SWING LOUVER switch 
is pressed, the louver will not stop immediately. The louver will 
move one extra swing. If the louvers are moved due to cleaning 
or for any reason, set Auto Setting mode to place the four 
louvers in  in the same position.
-
Do not turn the air louver by hand. If moved, the louver mechanism could be damaged! 
(In all units)
CAUTION:
Wall Type (RPK): 
  Adjust the vertical defl ectors by hand to discharge air in the required direction.
  Do not swing 1 blade at left side and 2 blade at right side of the vertical defl ection.
Automatic Setting of louver
  When the unit operation is stopped, two air louvers are stopped at closing position 
automatically.
-
-
Ceiling Type (RPC): 
  The vertical defl ector consists of four sets of defl ectors. Adjust the vertical defl ectors 
by hand to discharge air in the required direction.
NOTE:
For models without automatic swing louver the above indications are not 
available through R.C.S. The swing Louver should be adjusted by hand 
in this case.
•
-
RPC (Ceiling type)
Indication
Louver angle 
(aprox.)
 Horizontal
Approx.
15°
Approx.
30°
Approx.
40°
Approx.
50°
Approx.
60°
Approx.
80°
Cooling.
Heating
  Angle range
  Recommended angle
Angle range
Angle range
RPK (Wall type)
Indicación
Louver angle 
(aprox.)
Approx.
35°
Approx.
40°
Approx.
45°
Approx.
50°
Approx.
55°
Approx.
60°
Approx.
70°
Cooling.
Louver angle 
(aprox.)
Approx.
40°
Approx.
45°
Approx.
50°
Approx.
55°
Approx.
60°
Approx.
65°
Approx.
70°
Heating
  Angle range
  Recommended angle
Angle range
Angle range
RCD (2-Way cassete type)
Indication
Louver angle 
(aprox.)
Approx.
40°
Approx.
45°
Approx.
50°
Approx.
55°
Approx.
60°
Approx.
65°
Approx.
70°
Cooling.
Heating
  Angle range
  Recommended angle
Angle range
Angle range
RCI (4-Way cassete type)
Indication
Louver angle 
(aprox.)
Approx.
20°
Approx.
25°
Approx.
30°
Approx.
35°
Aprox.
45°
Approx.
55°
Approx.
70°
Cooling.
Heating
  Angle range
  Recommended angle
Angle range
Angle range
One set
Vertical defl ector 
Horizontal defl ector 
Horizontal defl ector 
Vertical defl ector