EasyManua.ls Logo

Hitachi S1-00073HFE - Page 135

Hitachi S1-00073HFE
235 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
S1 series standard inverter
-130-
Function
code
Name
Detailed parameter description
Default
value
Modify
P07.48
Output terminal state of the last fault
0
P07.49
Running frequency of the last but one fault
0.00Hz
P07.50
Ramps reference frequency of the last but one fault
0.00Hz
P07.51
Output voltage of the last but one fault
0V
P07.52
Output current of the last but one fault
0.0A
P07.53
Bus voltage of the last but one fault
0.0V
P07.54
Max. temperature of the last but one fault
0.0°C
P07.55
Input terminal state of the last but one fault
0
P07.56
Output terminal state of the last but one fault
0
P08 group Enhanced functions
P08.00
Acceleration
time 2
See P00.11 and P00.12 for detailed definitions.
S1 series inverter defines four groups of
acceleration/deceleration time, which can be
selected by multi-function digital input terminal
(P05 group). The acceleration/deceleration time
of the inverter is the first group by default.
Setting range: 0.03600.0s
Depend
on
model
P08.01
Deceleration
time 2
Depend
on
model
P08.02
Acceleration
time 3
Depend
on
model
P08.03
Deceleration
time 3
Depend
on
model
P08.04
Acceleration
time 4
Depend
on
model
P08.05
Deceleration
time 4
Depend
on
model
P08.06
Running
frequency of
jogging
This function code is used to define the reference
frequency of the inverter during jogging.
Setting range: 0.00HzP00.03 (Max. output
frequency)
5.00Hz
P08.07
Acceleration time
of jogging
Jogging acceleration time is the time needed for
the inverter to accelerate from 0Hz to Max. output
frequency (P00.03).
Jogging deceleration time is the time needed from
decelerating from Max. output frequency (P00.03)
to 0Hz.
Depend
on
model
P08.08
Deceleration time
of jogging

Table of Contents

Related product manuals