For parameter configuration
[AF120] to [AF152]
Brake control function
AF120 Contactor control enable,
1st-motor
00(Disable)/
01(Enable:
primary side)
02(Enable:
secondary side)
AF121 Run delay time,
1st-motor
AF122 Contactor off delay time,
1st-motor
AF123 Contactor response
check time, 1st-motor
AF130
Brake control enable, 1st-motor
00(Disable)/
01(Brake control 1:
Common)/
02(Brake control 1:
Separate)/
03(Brake control 2)
AF131 Brake release wait time,
1st-motor(Forward)
AF132 Brake wait time for
Accel., 1st-motor(Forward)
AF133 Brake wait time for
stopping, 1st-motor (Forward)
AF134 Brake confirmation signal
wait time, 1st-motor (Forward)
AF135 Brake release frequency
setting,1st-motor (Forward)
AF136 Brake release current
setting, 1st-motor (Forward)
Inverter rated
current
×(0.0 to 2.0)(A)
Inv
rated
current
×
1.0(A)
AF137 Brake frequency,
1st-motor (Forward)
AF138 Brake release wait time ,
1st-motor (Reverse)
AF139 Brake wait time for
Accel. , 1st-motor (Reverse)
AF140 Brake wait time for
Stopping, 1st-motor (Reverse)
AF141 Brake wait time for
confirmation,
1st-motor (Reverse)
AF142 Brake release frequency
setting,
1st-motor (Reverse)
AF143 Brake release current
setting, 1st-motor (Reverse)
Inverter rated
current
×(0.0 to 2.0)(A)
Inv
rated
current
×
1.0(A)
AF144 Brake frequency,
1st-motor (Reverse)
AF150 Brake open delay time,
1st-motor
AF151 Brake close delay time,
1st-motor
AF152 Brake response check
time, 1st-motor
AF153 Servo lock/ DC injection time
at start, 1st-motor
AF154 Servo lock/ DC injection time
at stop, 1st-motor
・The parameters [AF120] to [AF153] set the brake control and
the contactor control.
In addition to these parameters, the brake control function
uses the input terminal 037[BOK] Answer back from Brake
and the output terminal 037[BRK] Brake release, 038[BER]
Brake error. And the contactor control function uses the input
terminal 107[COK] Contactor check signal and the output
terminal 039[CON] Contactor control.
For more information, contact your supplier or local Hitachi inverter
sales office.
2nd motor When Intelligent Input terminal 024[SET] is enabled.
AF201 DC braking selection, 2nd-motor
AF202 Braking type selection, 2nd-motor
AF203 DC braking frequency, 2nd-motor
AF204 DC braking delay time, 2nd-motor
AF205 DC braking force setting, 2nd-motor
AF206 DC braking active time at stop, 2nd-motor
AF207 DC braking operation method selection,
2nd-motor
AF208 DC braking force at start, 2nd-motor
AF209 DC braking active time at start, 2nd-motor
AF220 Contactor control enable, 2nd-motor
AF221 Run delay time, 2nd-motor
AF222 Contactor off delay time, 2nd-motor
AF223 Contactor response check time, 2nd-motor
AF230 Brake control enable, 2nd-motor
AF231 Brake release wait time,
2nd-motor (Forward)
AF232 Brake wait time for accel., 2nd-motor
(Forward)
AF233 Brake wait time for stopping, 2nd-motor
(Forward)
AF234 Brake confirmation signal wait time,
2nd-motor(Forward)
AF235 Brake release frequency setting, 2nd-motor
(Forward)
AF236 Brake release current setting, 2nd-motor
(Forward)
AF237 Braking frequency, 2nd-motor (Forward)
AF238 Brake release wait time, 2nd-motor (Reverse)
AF239 Brake wait time for accel., 2nd-motor
(Reverse)
AF240 Brake wait time for stopping,
2nd-motor(Reverse)
AF241 Brake confirmation signal wait time,
2nd-motor(Reverse)
AF242 Brake release frequency setting,
2nd-motor(Reverse)
AF243 Brake release current setting, 2nd-motor
(Reverse)
AF244 Braking frequency, 2nd-motor (Reverse side)
AF250 Brake open delay time, 2nd-motor
AF251 Brake close delay time, 2nd-motor
AF252 Brake response check time, 2nd-motor
AF253 Servo lock/DC injection time at
start,2nd-motor
AF254 Servo lock/DC injection time at stop,
2nd-motor