4-17
Chapter 4
For parameter configuration
[AG101] to [AG113]
Resonant frequency avoidance (Jump)
Code/Name
Range (unit)
Initial
value
AG101 Jump frequency 1, 1st-motor
0.00 to
590.00(Hz)
0.00
AG102 Jump frequency width 1,
1st-motor
0.00 to 10.00(Hz)
0.00
AG103 Jump frequency 2, 1st-motor
0.00 to
590.00(Hz)
0.00
AG104 Jump frequency width 2,
1st-motor
0.00 to 10.00(Hz)
0.00
AG105 Jump frequency 3, 1st-motor
0.00 to
590.00(Hz)
0.00
AG106 Jump frequency width 3,
1st-motor
0.00 to 10.00(Hz)
0.00
Using above parameters prevents from the passing of the
output frequency in a resonant point. Output frequency
changes discontinuously.
Motor Accel/Decel time dwell (Hold)
Code/Name
Range (unit)
Initial
value
AG110 Acceleration stop frequency
setting, 1st-motor
0.00 to
590.00(Hz)
0.00
AG111 Acceleration stop time setting,
1st-motor
0.0 to 60.0(s)
0.0
AG112 Deceleration stop frequency
setting, 1st-motor
0.00 to
590.00(Hz)
0.00
AG113 Deceleration stop time setting,
1st-motor
0.0 to 60.0(s)
0.0
When performing acceleration/deceleration operation with
the large inertial load, acceleration/deceleration is
temporarily stopped so that [E001] overcurrent error and
[E007] overvoltage error do not occur.
If the Intelligent input terminal 100[HLD] is in ON state, the
acceleration and deceleration will be stopped (Hold
activation).
[AG-20] to [AG213]
Jogging function
Code/Name
Range (unit)
Initial
value
AG-20
Jogging
frequency
0.00 to 10.00(Hz)
6.00
AG-21
Jogging
stop mode
selection
00 (Free run at Jogging stop (Disable at run))
01 (Deceleration stop at Jogging stop
(Disable at run))
02 (Dynamic brake at Jogging stop
(Disable at run))
03 (Free run at Jogging stop (Enable at run))
04 (Deceleration stop at Jogging stop
(Enable at run))
05 (Dynamic brake at Jogging stop
(Enable at run))
00
The jogging frequency is outputted when Input terminal
029[JG] is active (ON) and the RUN command is given.
The above parameters set the jogging frequency and
stop method of jogging operation.
In the case [AG-21]=01
2nd motor When Intelligent Input terminal 024[SET] is enabled.
Code/Name
Range
(unit)
Initial
value
AG201 Jump frequency 1, 2nd-motor
Same as AG101
AG202 Jump frequency width 1, 2nd-motor
Same as AG102
AG203 Jump frequency 2, 2nd-motor
Same as AG103
AG204 Jump frequency width 2, 2nd-motor
Same as AG104
AG205 Jump frequency 3, 2nd-motor
Same as AG105
AG206 Jump frequency width 3, 2nd-motor
Same as AG106
AG210 Acceleration stop frequency setting,
2nd-motor
Same as AG110
AG211 Acceleration stop time setting 2nd-motor
Same as AG111
AG212 Deceleration stop frequency setting,
2nd-motor
Same as AG112
AG213 Deceleration stop time setting,,
2nd-motor
Same as AG113
frequency
Time
[AG112]
[AG113]
A155
[AG111]
A155
[AG110]
Output
frequency
Frequency
reference
[AG101]
[AG103]
[AG105]
[AG102]
[AG102]
[AG104]
[AG104]
[AG106]
[AG106]
JG
FW
RV
Output
Frequency
[AG-20]

Related product manuals