For parameter configuration
[UA-01] to [UA-19]
■Parameter mode (U code)
Password setting
UA-01 Password for display(UA-10)
UA-02 Password for softlock(UA-16)
・If the password other than 0000 is set to [UA-01]/[UA-02] , the
parameter [UA-10]/[UA-16] are locked and cannot be
changed.
When the password is set for [UA-01]/[UA-02] again, the
locked state is released.
・Please note that if you forget the password, locked state
cannot release !
Keypad display mode
UA-10 Display
restriction selection
00(Full display)/
01(Function-specific display)/
02(User setting)/
03(Data comparison display)/
04(Monitor only)
・This parameter selects the display mode of the keypad.
・For more information, contact your supplier or local
Hitachi inverter sales office .
Accumulated power display adjustment/clear
UA-12 Accumulated input power
monitor clear
UA-13 Display gain for the
accumulated input power monitor
UA-14 Accumulated output
power monitor clear
UA-15 Display gain for the
accumulated output power monitor
・If input terminal 039[KHC] is turned ON, the
accumulated input power can be clear.
・If input terminal 040[OKHC] is turned ON, the
accumulated output power can be clear.
Software lock operation setting
UA-16 Soft-Lock selection
00([SFT] terminal)/
01(Always enable)
UA-17 Soft-Lock target
selection
00(All data)/
01(All, except speed
related values )
・Above parameters set the software lock operation.
Keypad copy function restriction *1)
00(Not able to R/W)
01(Able to R/W)
・Restricts the copy function(Read/Write).
・SH1 series do not support this function.
Keypad low battery warning *1)
UA-19 Low battery warning
enable
00(Disable)/
01(Warning [LBK] )/
02(Error[E042])
・This parameter sets the behavior when the keypad
battery is low.
・SH1 series do not support this function.
[UA-20] to [UA-62]
Keypad communication lost operation
UA-20 Action
selection at keypad
disconnection
00(Error)/
01(Error output after
deceleration stop)/
02(Ignore)/03(Free run stop)/
04(Deceleration stop)
2
nd
-motor/option parameter display selection
UA-21 2nd-motor
parameter display
selection
UA-22 Option
parameter display
selection
・If options and 2nd-motor are not used, it is recommended to
hide their parameters.
・For more information, contact your supplier or local Hitachi inverter
sales office.
User-parameter setting function
UA-30 User-parameter auto setting
function enable
UA-31 User-parameter 1 selection
no/
(Parameters
excluding
[UA-31] to
[UA-62])
UA-32 User-parameter 2 selection
UA-33 User-parameter 3 selection
UA-34 User-parameter 4 selection
UA-35 User-parameter 5 selection
UA-36 User-parameter 6 selection
UA-37 User-parameter 7 selection
UA-38 User-parameter 8 selection
UA-39 User-parameter 9 selection
UA-40 User-parameter 10 selection
UA-41 User-parameter 11 selection
UA-42 User-parameter 12 selection
UA-43 User-parameter 13 selection
UA-44 User-parameter 14 selection
UA-45 User-parameter 15 selection
UA-46 User-parameter 16 selection
UA-47 User-parameter 17 selection
UA-48 User-parameter 18 selection
UA-49 User-parameter 19 selection
UA-50 User-parameter 20 selection
UA-51 User-parameter 21 selection
UA-52 User-parameter 22 selection
UA-53 User-parameter 23 selection
UA-54 User-parameter 24 selection
UA-55 User-parameter 25 selection
UA-56 User-parameter 26 selection
UA-57 User-parameter 27 selection
UA-58 User-parameter 28 selection
UA-59 User-parameter 29 selection
UA-60 User-parameter 30 selection
UA-61 User-parameter 31 selection
UA-62 User-parameter 32 selection
・Above parameters store the changed parameters history in
[UA-31] to [UA-62] when [UA-30] = 01, or set the data to be
displayed when [UA-10] = 02. ([UA-10] = 02 setting is priority)