EasyManua.ls Logo

Hitachi SJ Series - Page 38

Hitachi SJ Series
74 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4-24
Chapter 4
Safety Function
e.g. Case: SBC-A activating after STO-A activating
[1-31]SBC-A Time linkage=00(SBC after STO),
[1-12]STO-A Release mode =01(With safety signal) and [1-
36]SBC-A release level=0.00%:
e.g. Case: SBC-A activating before STO-A activating
[1-31]SBC-A Time linkage=01(SBC before STO),
[1-12]STO-A Release mode =01(With safety signal) and [1-
36]SBC-A release level=0.00%:
SBC-A
Input
Output
STO-A monitoring
Motor speed
SBC-A control
Open
Short
STO-A completed
Active
Inactive
Active
Inactive
Inactive
Active
Releasable
[1-11]STO-A Keep time
[1-32]Wait time for SBC-A after STO-A
[1-35]SBC-A STO-A Release wait time
SBC-A
Input
Output
STO-A monitoring
Motor speed
SBC-A control
Open
Short
STO-A completed
Active
Inactive
Active
Inactive
Inactive
Active
Releasable
[1-11]STO-A Keep time
[1-33]Wait time for SBC-A before STO-A
[1-35]SBC-A STO-A Release wait time

Other manuals for Hitachi SJ Series